Use pipe-joint compound made for use with Natural and
LP/Propane
gas to seal all gas connections.
If flexible
connectors are used, be certain connectors are not kinked.
The supply line must be equipped with an approved
manual shutoff valve. This valve should be located
in the same room as the range and should be in a
location that allows ease of opening and closing. Do
not block access to the shutoff valve. The valve is for
turning on or shutting off gas to the appliance.
t_
The conversion must be performed by a qualified
service technician
in accordance with the
manufacturer's
instructions
and all local codes and
requirements.
Failure to follow these instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility
for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Manual Shutoff Valve
-
li%
Open position
Figure 4
Once regulator is in place, open the shutoff valve in
the gas supply line. Wait a few minutes for gas to
move through the gas line.
Check for leaks. After connecting
the range to the gas
supply, check the system for leaks with a manometer.
If a manometer
is not available, turn on the gas supply
and use a liquid leak detector (or soap and water) at all
joints and connections to check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
Tighten
all connections
as necessary to prevent gas
leakage in the range or supply line.
Disconnect
this range from the gas supply piping
system during any pressure testing of that system at
test pressures greater than 1/2 psig (3.5 kPa or 14"
water column).
Isolate
the range from the gas supply piping
system by closing its individual
manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5 kPa or 14" water column).
6, Electrical
Requirements
120 volt, 60 Hertz, properly grounded dedicated circuit
protected
by a 15 amp circuit breaker or time delay
fuse. NOTE: This range is not recommended
to be
installed with a Ground Fault Interrupt
(GF[).
Do not use an extension
cord with this range.
Grounding
Instructions
IMPORTANT
Please read carefully.
For personal
safety,this appliance
must be
properly
grounded.
The power cord of this appliance is equipped with a
3-prong (grounding)
plug which mates with a standard
3-prong grounding wall receptacle (see Figure 5) to
minimize the possibility of electric shock hazard from
the appliance.
The wall receptacle and circuit should be checked by
a qualified electrician to make sure the receptacle is
properly grounded.
Preferred
Method
not, under any'_
Grounding type
circumstances,
|
wall receptack
cut, remove,
/
or bypass the
|
grounding
prong.J
Figure 5
Power supply cord with
3-prong grounding plug.
5. LP/Propane
Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use
with natural gas.
The range comes supplied with fixed orifices for
converting it to LP gas. These orifices are located in a
bag marked FOR LP/PROPANE GAS CONVERSION. The
instructions for surface, oven and broil burner conversion
are packaged with the orifices.
Where a standard 2-prong wall receptacle is installed,
it is the personal responsibility
and obligation
of the
consumer to have it replaced by a properly grounded
3-prong wall receptacle.
Do not, under any circumstances,
cut or remove
the third
(ground)
prong from
the power cord.
Disconnect electrical supply cord from
wall receptacle before servicing range.