Lp/Propane Gas Conversion; Electrical Requirements - Frigidaire PLGF659GCA Installation Instructions Manual

36" gas range
Hide thumbs Also See for PLGF659GCA:
Table of Contents

Advertisement

Available languages

Available languages

allowsease of opening andclosing. Donot blockaccess
to theshutoffvalve. T hevalve isfor turningonor
shutting off gasto theappliance.
Openposition
Figure4
Once regulator i s in place, o penthe shutoffvalve in the
gassupply line.Waita few minutes f or gasto move
through thegasline.
Check for leaks.Afterconnecting t he range tothe gas
supply, c heck the system for leaks with a manometer. If
a manometer is notavailable, turn onthegassupply and
usea liquidleakdetector ( orsoapandwater)at all
jointsandconnections to check for leaks.
Donot usea flameto check for leaks
fromgasconnections. Checking f or leaks witha flame
mayresult i n afire or explosion.
Tightenal! connections asnecessary to prevent g as
leakage inthe range or supply line.
Disconnect t his rangefromtile gassupply piping
system duringanypressure t esting of thatsystem attest
pressures greater t han1/2psig(3.5kPa or 14" water
column).
Isolatethe rangefrom the gassupplypiping system
byclosing itsindividual manual shutoffvalveduringany
pressure t estingof thegassupply pipingsystem attest
pressures equal t o or lessthan1/2psig(3.5kPa or 14"
watercolumn).
5. LP/Propane
Gas Conversion
This appliance can be used with Natural gas or LP/Propane
gas. It is shipped from the factory for use with natural gas.
The range comes supplied with fixed orifices for converting
it to LP gas. These orifices are located in a bag marked
FOR LP/PROPANEGAS CONVERSION.The instructions for
surface, oven and broil burner conversion are packaged
with the orifices.
The conversion must be performed by a qualified service
technician in accordance with the manufacturer's
instructions and all local codes and requirements. Failure
to follow these instructions could result in serious injury
or property damage. The qualified agency performing
this work assumes responsibility for tile conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
5. Electrical
Requirements
120 volt, 60 Hertz, properly grounded dedicated circuit
protected by a 15 amp circuit breaker or time delay fuse.
Note: This range is not recommended to be installed
with a Ground Fault Interrupt (GFI).
Do not use an extension
cord with this range.
Grounding
Instructions
IMPORTANT Please read carefully.
For personal
safety,
this appliance
must be properly
grounded.
The power cord of this appliance is equipped with a 3-
prong (grounding) plug which mates with a standard 3-
prong grounding wall receptacle (see Figure 5) to
minimize the possibility of electric shock hazard from tile
appliance.
The wall receptacle and circuit should be checked by a
qualified electrician to make sure the receptacle is
properly grounded.
Preferred Method
/__a_!,l
Grounding type
wall rece
Figure 5
Power supply cord with 3-
prong grounding plug.
Where a standard 2-prong wall receptacle is installed, it
is the personal responsibility and obligation of tile
consumer to have it replaced by a properly grounded 3-
prong wall receptacle.
Do not, under any circumstances, cut or remove the
third (ground}
prong from the power
cord.
Disconnect electrical supply cord from
wall receptacle before servicing range.