Download Print this page

Advertisement

Quick Links

Installation
Instructions
l'°so r'e
1@
Questions on Installation?
Call: 800.GE.CARES (US)
or visit our web site at: www.GEAppliances.com
(US)
BEFOREYOU BEGIN
Read these instructions
completely
and
carefully.
•IN PORTANT-
Save these instructions for
local inspector's use.
•IMPORTANT-
Observe all governing codes
and ordinances.
• Note to Installer - Besureto leavethese
instructionswith the customer.
• Note to Customer - Keep these instructions
with your Owner's Hanual for future reference.
• Before the old dryer is removed from service or
discarded, remove the dryer door.
• inspect the dryer exhaust outlet and straighten
the outlet walls if they are bent.
• Service information and the wiring
diagram
are located in the control console.
• Do not allow children on or in the appliance.
Closesupervisionof childrenis necessarywhen
the appliance is usednear children.
• install the dryer wherethe temperature is
above SO°F for satisfactory operation of the
dryer control system.
• Productfailure due to improper installationis
not coveredunder the Warranty.
WARNING
RISK OF FIRE
• To reducethe risk of severe injury or death, follow all installation instructions.
• Clothesdryer installation must be performed by a qualified installer.
• Install the clothesdryer according to these instructionsand inaccordance with local
codes.Inthe absenceof local codes,installation must comply with National FuelGas
Code,ANSIZ22].l/NFPA54 or the CanadianNatural Gasand PropaneInstallationCode,
CSAB149.1.
• CaliforniaSafeDrinkingWaterand ToxicEnforcementAct.
This act requiresthe governor of Californiato publish a list of substancesknown to the
state to cause cancer,birth defects or other reproductive harm and requires businesses
to warn customers of potential exposureto such substances.Gasappliancescan
causeminor exposureto four of these substances,namely benzene,carbon monoxide,
formaldehyde and soot, caused primarily by the incomplete combustion of natural gas
or LPfuels. Properlyadjusted dryerswiti minimizeincomplete combustion. Exposure
to these substancescan be minimized further by properly venting the dryerto the
outdoors.
• This dryer must be exhaustedto the outdoors.
• Useonly 4" rigid metal ducting for exhaustingthe clothesdryer to the outdoors.
• DO NOTinstall a clothesdryer with flexible plastic ducting materials.If flexible metal
(semi-rigidor foil-type) duct is installed,it must be ULlisted and installedin accordance
with the instructions found in "ConnectingThe DryerToHouseVent" on page 6 of this
manual.Flexibleventing materials are known to collapse,be easiiy crushed,and trap
lint.Theseconditions wilt obstruct dryerairflow and increasethe risk of fire.
• Donot install or store this appliancein any locationwhere it could be exposedto water
and or weather.
• Savethese instructions.(Installers:Besure to leave these instructionswith the
customer).
In the state of Massachusetts:
• Installation must be performed by a qualified or licensed contractor,
plumber, or gasfitter qualified or licensed by the state.
• When using ball-type gas shut-offvalves, they shall be T-handle type.
• A flexible gas connector, when used, must not exceed 3 feet.
TOOLS YOU
WILL NEED
(x2)
10" ADJUSTABLE
WRENCH
ES
,
ic................. _)
8"PIPE W RENCH
LEVEL
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
)
M ATERIALS YOUWILL NEED
4"DIA. METAL DUCT
I====_
(RECOMMENDED)
4"DIAM METAL ELBOW
4"DIA. F LEXIBLE
METAL ( SEMI-RIGID)
ULLISTED TRANSITION
DUCT
(IFNEEDED)
KIT WXO8X10077
(INCLUDES
2 ELBOWS)
4"DIA. F LEXIBLE
METAL (FOIL T YPE)
ULLISTED TRANSITION
DUCT
(IFNEEDED.)
Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step ] Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications
(see section 6).
Step 4 Remove the Foam Shipping Pads (see section 1).
Step 5 Move the Dryer to the Desired Location.
Step 6 Level Your Dryer (see section 8).
Step 7 Connect the Gas Supply (see section ]) and check for
leaks (see section 4).
PIPE
SOAP SOLUTION
FOR L EAK DETECTION
EXHAUST
HOOD COMPOUND
4"DUCT CLAMPS
DUCT TAPE
OR
SAFETY
GLASSES
4"SPRING
CLAMPS
FLEXIBLE
GAS L INE C ONNECTOR
GLOVES
Step 8 Connect the External Exhaust (see section 7).
Step 9 Connect the Power Supply (see section 5).
Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owner's Manual and the Installation
Instructions in a location where they will be noticed
by the owner.
For Alcove or Closet Installation
see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured
Home see section 11.
For garage installation (if allowed by local codes), see section 12.
234D1582PO03
31-16225-2
03-12 GE

Advertisement

loading

Summary of Contents for GE DNCK440GG9WC

  • Page 1 Installation Instructions Questions on Installation? Call: 800.GE.CARES (US) or visit our web site at: www.GEAppliances.com (US) BEFOREYOU BEGIN WARNING RISK OF FIRE Read these instructions completely • To reducethe risk of severe injury or death, follow all installation instructions.
  • Page 2: Gas Requirements

    Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and J_ in. rear. Consideration must be given to provide adequate clearance for installation and service. [] GAS REQUIREMENTS PREPARING FOR INSTALLATION tLWARNING...
  • Page 3 Installation Instructions IYI RECONNECTING Listed connector ANSt Z21.24 / CSA 6.10 APPLYPIPECOMPOUND TO ALL MALETHREADS. 1/8" NPT PIPE NEW METAL PLUG FOR FLEXIBLE GAS INLET PRESSURE LINE CONNECTOR SHUT-OFF ADAPTER 3/8" NPT ELBOW PIPE SIZE ITEMSNOT SUPPLIED LEAST1/2" Note: The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location.
  • Page 4 Installation Instructions ELECTRICAL CONNECTION I-_ EXHAUST INFORMATION INFORMATION WARNING CANADA AND IN THE UNITED STATES,THE REQUIRED EXHAUST DUCT WARNING - TOREDUCE T HE DIAMETER IS 4 IN (102mm). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST RISK OF FIRE, ELECTRICAL SHOCK, LENGTH TABLE.
  • Page 5 Installation Instructions STANDARD REAR EXHAUST r-71EXHAUST CONNECTION (Vented above floor level} WARNING - TOREDUCE T HE ELBOW H IGH LY RISK OF FIRE OR PERSONAL INJURY: RECOMMENDED • This clothes dryer must be exhausted to the outdoors. • We recommend that you install your dryer before installing your washer.
  • Page 6 Installation Instructions CONNECTING THE DRYER TO HOUSE VENT RIGID METALTRANSITION DUCT • Forbest drying performance,a rigid metal transition duct is recommended. • Rigid metaltransitions ductsreduce the riskof crushing and kinking. UL-LISTED FLEXIBLE METAL (SEMI-RIGID TRANSITION DUCT • If rigid metal duct cannot be used,then UL-listedflexible EXCESSIVE metal (semi-rigid)ducting can be used(KitWX08XZ0077).
  • Page 7 Installation Instructions ADDING NEW DUCT I_IGARAGE INSTALLATION (IF ALLOWED BY LOCAL CODES) FIXING HOLE • Dryers installed in garages must be elevated 18 inches (46cm) above the floor. PORTION "A" IT3-1DRYEREXHAUST TO RIGHT, LEFT OR BOTTOM CABINET WARNING - BEFORE P ERFORMING THIS EXHAUST INSTALLATION, BE SURE LEFT S IDE...
  • Page 8 Installation Instructions ADDING ELBOW FOR EXHAUST CHANGING DIRECTION OF DOOR THROUGH BOTTOM OF CABINET OPENING • Insert the elbow through the rear opening and connect it to the dryer internal duct. • Apply duct tape on the joint between the dryer internal REMOVE4 HOLEPLUGSAND duct and elbow, as shown on page 7.
  • Page 9: Water Supply Requirements

    Installation Instructions 1_ CONNECTING INLET HOSES CONNECTING INLET HOSES (cont.) (on some models) 8.Turn the water faucet on. 9. Check for leaks around the "Y" connector, faucet and To produce steam, the dryer must connect to the cold water supply. Since the washer must also connect to the hose couplings.
  • Page 10 Notes...
  • Page 11 Notes...