BEFORE YOU BEGIN
Readthese instructionscompletely and carefully.
• IMPORTANT- save
these instructions
for local inspector's use.
• IMPORTANT-
Observeall governing
codesand ordinances.
• Note to Installer - Be sureto leavethese
instructionswith the customer.
• Note to Customer - Keepthese instructions
with your Owner's Manualfor future reference.
• Beforethe old dryer is removedfrom serviceor
discarded,removethe dryer door.
• inspectthe dryer exhaustoutlet and straighten
the outlet walls if they are bent.
• Serviceinformation and the wiring dia-gram
are located in the control console.
• Donot allow childrenon or in the appliance.
Closesupervisionof children is necessarywhen
the applianceis used near children.
• install the dryer where the temperature is
aboveSO°F for satisfactory operationof the
dryercontrol system.
• Product failure due to improper installation
is not covered under the warranty.
NOTE: Installation and service of this dryer
requires basic mechanical and electrical
skills. It is gour responsibilitg
to contact
a qualified installer to make the electrical
connections.
TOOLS YOU WILL NEED
SLIP JOINT P LIERS
FLAT B LADE SCREWDRIVER
PHILLIPS
SCREWDRIVER
%
WARNING
RISK OF FIRE
• To reduce the risk of severe injury or death, follow all installation
instructions.
• Clothes dryer installation must be performed by a qualified installer.
• Install the clothes dryer according to these instructions and in
accordance with local codes.
• This dryer must be exhausted to the outdoors.
• Use only 4" rigid metal ducting for exhausting the clothes dryer to
the outdoors.
• DO NOT install a clothes dryer with flexible plastic ducting materials.
If flexible metal (semi-rigid or foil-type) duct is installed, it must be
UL listed and installed in accordance with the instructions found
in Connecting The Dryer To House Vent on page 5 of this manual.
Flexible venting materials are known to collapse, be easily crushed,
and trap lint. These conditions will obstruct dryer airflow and
increase the risk of fire.
• Do not install or store this appliance in any location where it could
be exposed to water and or weather.
• Save these instructions. (Installers: Be sure to leave these
instructions with the customer).
• Install the clothes dryer according to the manufacturer's
instructions and local codes.
TOOLS YOU WILL NEED
)
41DIAMETALDUCT
V/ll
(RECOMMENDED)
",,../..jj
# DUCT
# DIA _v_ETAL
CLAMPS (2)
ELBOW
OR
#SPRING
CLAMPS (2)
DUCTTAPE
41DIAFLEXIBLE
METAL (SEMDRIGID)
ULLISTED TRANSITION
DUCT
(IF NEEDED)
KFWXBBXlOB77
)INCLUDES 2ELBOWS)
4'DIAFLEXIBLE METAL (FOIL TYPE)
ULLISTED TRANSITION
DUCT(IF N EEDED)
EXHAUST
HOOD
GLOVES
SAFETY
GLASSES
]/#'STRAIN
RELIEF
ULRECOGNIZED
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
ULRATED
1BO/24OV ]OA
WITH 3 OR 4 PRONGS
IDENTIFY THE PLUG
TYPE A SPER THE
HOUSE R ECEPTACLE
BEFORE PURCHASING
LINE CORD
Step 1 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 2 Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 3).
Step 3 Remove the Foam Shipping Pads (see section 1).
Step 4 Move the Dryer to the Desired Location.
Step 5 Connect the Power Supply (see section 2).
Step 6 Connect the External Exhaust (see section 4).
Step 7 Level Your Dryer (see section 5).
Step 8 Check the Operation of the Power Supply & Venting.
Step 9 Place the Owner's
Manual and the Installation
Instructions
in a location where they will be noticed by the
owner.
For Alcove or Closet Installation,
see section 6.
For Bathroom or Bedroom
Installation,
see section 7.
For Mobile or Manufactured
Home see, section 8.
For garage installation (if allowed by local codes), see section 9.
For side or bottom
exhaust, see section 10.
234D1582PO04
31-16224-2
03-12 GE

Advertisement

Table of Contents
loading

Summary of Contents for GE DNCK440EG7WC

  • Page 1 Installation Electric Drger Instructions Questions on Installation? Call: 800.GE.CARES (US) or visit our web site at: www.GEAppliances.com (US) BEFORE YOU BEGIN WARNING RISK OF FIRE Readthese instructionscompletely and carefully. • To reduce the risk of severe injury or death, follow all installation •...
  • Page 2: Installation Instructions

    Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and ] in. rear. Consideration must be given to provide adequate clearance for installation and service. m PREPARING FOR INSTALLATION CONNECTING DRYER USING 4-WIRE...
  • Page 3: Exhaust Information

    Installation Instructions CONNECTING DRYER USING 3-WIRE INFORMATION EXHAUST CONNECTION WARNING -IN CANADA AND IN iFREQUIRED, BYLOCAL CODE, THE UNITED STATES, THE REQUIRED INSTALL EXTERNAL GROUND (NOT P ROVIDED)TO GROUNDED HAUST DUCT DIAMETER IS 4 IN (102ram). METAL C OLD WATER P iPE OR GREEN GROUND NOT USE DUCT LONGER THAN SPECIFIED...
  • Page 4: Installation

    Installation Instructions STANDARD REAR EXHAUST EXHAUST INFORMATION (cont) (Vented at floor level) SEALING OFJOINTS FOR STRAIGHT LINE INSTALLATION, • All joints should be tight to avoid leaks. The male end of CONNECT THE DRYER EXHAUST TO each section of duct must point away from the dryer. THE EXTERNAL EXHAUST HOOD •...
  • Page 5: Alcove Or Closet Installation

    Installation Instructions CONNECTING THE DRYERTO HOUSEVENT RIGIDMETAL TRANSITION DUCT • Forbest drying performance,a rigid metal transition duct is recommended. • Rigidmetal transitions ducts reducethe risk of crushing and kinking. UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT • If rigid metal duct cannot be used,then UL-listedflexible metal (semi-rigid) ducting can be used(KitWX08XZ0077).
  • Page 6 Installation Instructions ADDING NEW DUCT BY LOCAL CODES) FIXING HOLE ryers installed in garages must be elevated 18 inches ARAGE INSTALLATION (IF ALLOWED 6cm) above the floor. PORTION "A" 1161DRYEREXHAUST TO RIGHT, LEFT OR BOTTOM CABINET WARNING - BEFORE PERFORMING THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT...
  • Page 7 Installation Instructions • Apply duct tape as shown on the joint between the I-_ CHANGING DIRECTION OF dryer internal duct and the elbow. DOOR OPENING DUCT 1. Open the door and remove the filler plugs opposite the CAUTION: hinges. With the door completely open, remove the Internal duct joints must be bottom screws from each hinge on the dryer face.
  • Page 8: Water Supply Requirements

    Installation Instructions I_1 CONNECTING INLET HOSES I_1 CONNECTING INLET HOSES (cont.) (on some models) 7. Using pliers, tighten all the couplings with an additional two-thirds turn. To produce steam, the dryer must connect to the cold water supply. Since the washer must also connect to the NOTE: Do not overtighten.

This manual is also suitable for:

Gtdp520ed1wwGtdx185ed1ccGtdp280ed1wwGtdx400ed1wsGtdx180ed1wwGtdp180ed1ww ... Show all

Table of Contents