Electrical requirements
if codes
permit
and a separate
ground
wire
is used,
it is recommended
that
a
quaiified
eiectrician
determine
that the
ground
path
and wire
gauge
are in
accordance
with
iocai
codes.
This
range
must
be connected
to a
grounded
metal,
permanent
wiring
system.
Check
with
a qualified
electrician
if you
are not sure
range
is properly
grounded.
Do not ground
to a gas pipe.
Do not have
a fuse
in the neutral
or
ground
circuit.
Range
must
be connected
to the proper
electrical
voltage
and frequency
as
specified
on the model/serial
rating
plate.
(The
model/serial
rating
plate
is located
on the oven
frame
behind
the storage
drawer
panel.)
[_
A four-wire
or three-wire,
single+
phase,
120/240+volt,
60-Hz,
AC+only,
electrical
supply
(or three-wire
or four-
wire
120/208+volt
if specified
on the
model/serial
rating
plate)
is required
on a
separate,
40 amp
circuit,
fused
on both
sides
of the line.
[_
A time-delay
fuse
or circuit
breaker
is
recommended.
[_
The range
can be connected
directly
to the fused
disconnect
(or circuit
breaker
box)
through
flexible
armored
conduit.
This
range
can be direct
wired
to a four-
wire
or three-wire
aluminum
wiring
system.
See "Direct
wire
method:
Copper
or Aluminum
wire"
section.
Allow
two
to three
feet of slack in the line
so that
it can be moved
if servicing
is
ever
necessary.
A U.L.+listed
conduit
connector
must
be
provided
at each
end of the power
supply
cane
(at the range
and at the junction
box).
Wire
sizes and connections
must
conform
with
the rating
of the range
(40 amps).
[_
The wiring
diagram
is [ocated
on the
back of the range
or on the inside
of the
storage
drawer
in a clear
piasfic
bag.
Recommended
ground
method
It is the persona[
responsibility
and
obligation
of the customer
to contact
a
qualified
eiectrician
to assure
that the
eiectrica[
instaiiation
is adequate
and is in
conformance
with
the Nationa[
Eiectrica[
Code,
ANS[/NFPA
70 -- [atest
edition
_
and all[ [oca[ codes
and ordinances.
Power supply
cord is not supplied,
but is
available
through
your local electrical
supply house,
cabinet to countertop
4" (10.2 cm) min. clearance
from both sides of range to
side wall or other combustible
material above the countertop
++NOTE: 24" (61 cm) min.
t
when bottom of wood or
I
metal cabinet is protected
by not less than I/4"
I
(6.4 mm) flame retardant
millboard covered with not I
less than No. 28 MSG sheet I
steel, 0.015" (0.4 ram)
stainless steel, 0.024"
I
(0.6 mm) aluminum or
_
0.020" (0.6 ram) copper.
"_
30" (76.2 cm) rain. clearance
"_
between the top of the
cooking platform and the
bottom of an unprotected
wood or metal cabinet.
Wall receptacle -
8" (20.3 cm) to 22"
(55.9 cm) from either
cabinet, 5-I/2"
(14.0 cm) max. from
floor. Position
receptacle as shown.
mf connecting
to
a four-wire
system:
This
range
is manufactured
with
the
ground
connected
to the cabinet.The
ground
must
be revised
so the green
grounding
wire
of the four-wire
power
supply
cord
is connected
to the cabinet.
See "Four-wire
electrical
connection"
section.
When a four-wire
receptacle
of NEMA
Type 14-50R is used (see Figure 1, below),
a matching
U,h+iisted,
four+wire,
250+volt,
40 amp, range power supply cord (pigtail)
must be used,This
cord contains four
copper conductors
with either ring
terminals
or spade terminals
with
upturned
ends to connect the power
supply at the appliance
end, terminating
in a NEMAType
14-50P plug on the
supply end,The
fourth
(grounding)
conductor
must be identified
by a green
or green/yellow
cover and the neutral
conductor
by a white cover, Cord should
beType SRD or SRDT with a U,h-listed
strain relief and be at bast four feet long,
The minimum
conductor
sizes for the
copper four-wire
power cord are:
40 amp circuit
2 No,+8 conductors
1 No,+10 white neutral
1 No,°8
green
grounding
If connecting
to
a three-wire
system:
Local
codes
may
permit
the use of a
U.h-listed,
250-volt,
40 amp
range
power
supply
cord
(pigtail).This
cord
contains
three,
No.-10
copper
wires
and matches
a three-wire
receptacle
of NEMAType
10+50R, shown
in Figure
2. Connectors
on
the appliance
end must
be provided
at
the point
the power
supply
cord
enters
the appliance.
Do not pinch
the power
4-wire wall
3-wire wall
supply cord
receptacle (14-50R)
receptacle (I0-60R)
between the
range and the
wall.
Figure
1
Figure
2
Do not seal the
range to the
side cabinets.
Copies of the standards listed may be obtained
from:
+National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts, 02269