Jenn-Air JDR8895BAS13 Installation Instructions Manual page 15

30" (76.2 cm) double oven dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

2=
Attach terminal lugs to line 1 (black), bare (green) ground, and
line 2 (red) wires. Loosen (do not remove) the set screw on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten set screw to XX Ibs-
in. torque. See Bare Wire Torque Specifications
chart.
C
D
A. Terminal
lug
B. Set screw
C. Line
1 (black)
wire
D. Bare
(green)
ground
wire
E. Line 2 (red)
wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
3. Use 3/8"nut driver to connect the bare (green) ground wire to
the center terminal block post with one of the 10-32 hex nuts.
i
S_
L
D
C
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link
screw
D. Bare (green) ground wire
E. Line 2 (red)
F Terminal lug
4. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
v _,,_ ,,s
S %,,,Olq/"@C OFS
Explosion Hazard
Use a new CSA International
approved
gas supply
line.
Install a shut=off valve.
Securely
tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating
personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Typical flexible
connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a _SAe" c ombination
wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter (must have V2"male
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F V2" or 3/4"gas pipe
G. Use pipe-joint
compound.
H. Adapter
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jdr8895baw13Jdr8895bab13

Table of Contents