Jenn-Air JDRP436WP02 Installation Instructions Manual page 14

30" (76.2 cm), 36" (91.4 cm), 48" (121.9 cm) commercial style dual fuel convection ranges
Hide thumbs Also See for JDRP436WP02:
Table of Contents

Advertisement

Available languages

Available languages

NOTE: Range must be level for satisfactory
baking performance.
1. Place rack in oven.
2. Place level on rack and check levelness of the range, first
side to side; then front to back.
3. If range is not level, adjust the leveling rods. Turn leveling
rods located behind the kick plate to level range and to raise
or lower range to the desired countertop
height.
NOTE: All roller feet must be off the floor upon final installation.
L
B
A. Front leveling rod
B. Rear leveling rod
Install Burner Bases and Burner Caps
Install the burner base, making sure the igniter electrode is
properly aligned with the base. Place burner caps on top of
burner bases. If burner caps are not properly positioned, surface
burners will not light.
20,000 Btu/h Ultra Power
TM
Dual-Flame
Burner
A
A. Incorrect
B. Correct
15,000 Btu/h Professional Burner
5,000
Btu/h
Simmer/Melt
Burner
;
A. Incorrect
B. Correct
i
j
_'o '_Q i_lJ<)ll®'Y )(_@Is)
i ,._I . .;_B ....
='
....
= '
=< "
The griddle is factory installed.
1. Place drip tray in the well at the front of the griddle. Slide tray
toward the back until it stops.
\
A
\
A. Griddle drip tray
B. Griddle
2. Clean griddle before using. Refer to the Use and Care Guide.
Initial Lighting and Gas Flame Adjustments
Cooktop burners use electronic igniters in place of standing
pilots. When the cooktop control knob is turned to any position,
the system creates a spark to light the burner. This sparking
continues until the flame is lit or the knob is turned to Off.
Check Operation
of Cooktop
Burners
Push in and turn each control knob to the "LITE" position.
The surface burners and grill flames should light within
4 seconds. The first time a burner is lit, it may take longer than
4 seconds to light because of air in the gas line.
After verifying the proper burner operation, turn the control knobs
to OFR
If burners
do not light properly:
Turn cooktop control knob to the "OFF" position.
Check that the range is plugged in and the circuit breaker has
not tripped or the fuse has not blown.
Check that the gas shutoff valves are set to the "open"
position.
Check that burner caps are properly positioned on burner
bases.
Repeat start-up. If a burner does not light at this point, contact
your dealer or authorized service company for assistance.
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jdrp430wp01Jdrp548wp02Jdrp536wp02

Table of Contents