Jenn-Air JGR8750ADQ Installation Manual page 6

Gas 30-inch free-standing and slide-in

Advertisement

Gas SupplyConnectionsForRangesWith
Appliance PressureRegulator
LocatedIn The BottomOf Range
IFLEXIBLE
SUPPLY
LINE
0
N.P.T,
ELBOW
APPLIANCE
SHUT-OFF
PRESSURE
_
VALVE
REGULATOR
LOWER OVEN
TO CONNECT GAS SUPPLY
TO 1/2
N.P.T.
MALE
INLET
ADAPrOR
APPLIANCE
SHUT-OFF
PRESSURE
VALVE
REGUIATOR
"
_
LOWER OVEN
TO CONNECT
GAS SUPPLY
TO 1/2
N,P.T.
FEMALE
INLET
WHEN
THE
INSTALLER
HAS
COMPLETED
INSTALLATION
OF THE APPLIANCE,
LEAVE
THE APPLIANCE
PRESSURE
REGULATOR
SHUT-OFF
VALVE
IN THE "ON"
POSITION.
GasSupplyConnection ForRanges W ith
Appliance Pressure Regulator
LocatedUnder Main TopOf Range
FLEXIBLE
SUPPLY
LINE
\
ADAPTOR
FIG URE 4
Appliance
Pressure Regulator
& Alternate Connectors
* The appliance pressure regulator on your range may
differ from this illustration.
h.
Apply a non-corrosive
leak detection fluid to all joints
and fittings in the gas connection between the supply
line shut-off valve and the range. Include gas fittings
and joints in the range if connections were disturbed
during installation. Check for leaks! Bubbles
appearing around fittings and connections will indicate
a leak. If a leak appears, turn off supply line gas
shut-off valve, tighten connections, turn on the supply
line gas shut off valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A
FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF
ALL RESIDUE.
Remove shipping screw from ALL top burners.
(Conventional top burner models only). This is to hold
the burners in place on the burner bracket for shipping
purposes only. (See figure 5).
Adjust burner air shutter to the widest opening that will
not cause the flame to lift or blow off the burner when
cold.
NOTE: Correctly adjusted sealed burners, can have
flames that will lift or blow off without a pot over the
burner. These should be adjusted with a pot in place.
FIGURE 5
CHECKING
PRESSURE
OF HOUSE
PIPING
SYSTEM
1. The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 Ibs./sq. in. (3.5 kPa) (13.8 in. water
column).
.
The appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 Ibs./sq. in. (3.5 kPa) (13.8 in. water column).