Jenn-Air CCG2423 Installation Manual
Jenn-Air CCG2423 Installation Manual

Jenn-Air CCG2423 Installation Manual

30" and 36" sealed gas cooktop
Hide thumbs Also See for CCG2423:

Advertisement

SEALED GAS COOKTOPS
CCG2423 AND CCG2523
JGC7430 AND JGC7536
=JENN-AIR
403WEST FOURTHSTREET,NORTH ° NEWTON,IA 50208
IMPORTANT: Dimensions Shown in Both Inches and Centimeters.
IMPORTANT:
Be sure the appliancebeing installedis equippedfor the gas to be supplied.Refer to serial plateon undersideof burnerboxfor this
information.Do not attemptto convertthis appliancefor usewith a gasotherthanthe type specified.
76.2 cm
"4
Manifold
1 V21'
_
Entrance
Min. Clearance
3.81 cm
37&6"
2%"
8.73__¢m_k,i _
_ _
_
,_6.67cm
Lf
......_t_, _.._ MAN,FO_I
*II
ENTRANClE
J
121/32"
--
27.9 cm
4.21 cm
2" Min.
5.08 cm
9/16=
1.43 cm
32_
82.71 cm
2" Min.
Manifold
Entrance
53.34 cm
3.81cm
37/16"
8.73 cmL,
_
I
I
_
MANIFOLD
I
T-[-I
ENTeNtE
I
119/_..
35.57 cm
4,05 cm
2%"
/
,,__ 6.67 cm
SPECIALWARNING:
Improper installation, a djustment,alteration,service, m aintenance or useofappliance
can result in seriousinjuryor propertydamage.
NOTICE TO INSTALLER: LEAVETHESE INSTRUCTIONSWITH THE APPLIANCE.
NOTICE TO CONSUMER: RETAINTHESE INSTRUCTIONS FOR FUTURE REFERENCE.
8101 P401-60
(08-01-00)

Advertisement

Table of Contents
loading

Summary of Contents for Jenn-Air CCG2423

  • Page 1 SEALED GAS COOKTOPS =JENN-AIR CCG2423 AND CCG2523 JGC7430 AND JGC7536 403WEST FOURTHSTREET,NORTH ° NEWTON,IA 50208 IMPORTANT: Dimensions Shown in Both Inches and Centimeters. IMPORTANT: Be sure the appliancebeing installedis equippedfor the gas to be supplied.Refer to serial plateon undersideof burnerboxfor this information.Do not attemptto convertthis appliancefor usewith a gasotherthanthe type specified.
  • Page 2 LOCATIONOF YOUR JENN-AIR APPLIANCE PREPARATIONOF COUNTERTOP Locate this applianceawayfromcombustible m aterialssuch as window The countertopcutout must be preparedaccordingto the illustration o n curtainsand combustiblewall decorations. page 1 of these instructions. Minimum horizontalclearancebetween the edge of the applianceand CAUTION:Cutoutdimensions are critical.Dimensions mustbe measured combustible construction extending fromthe cookingsurfaceto 18"...
  • Page 3: Installationof Appliance

    INSTALLATIONOF APPLIANCE CONNECTINGAPPLIANCE TO GAS SUPPLY A TRAINEDSERVICEMANOR GAS APPLIANCEINSTALLERMUST The installation of thisappliance mustconform withlocalcodesor,inthe MAKETHE GASSUPPLY CONNECTION. L eaktestingoftheappliance absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-LatestEdition,or, in Canada,CAN!CGA-B149 InstallationCode, shall be conductedby the installer accordingto the instructions LatestEdition.
  • Page 4 2. IF THIS IS A 30" WIDE COOKTOP AND A JENN-AIR,MODEL W30XXXOR W131,ELECTRICWALLOVENIS TO BE INSTALLED BELOWTHISCOOKTOP. NOTE1: This applianceand its gasandelectricalsupplysourcesmustbe ILLUSTRATIVE GAS SUPPLY PIPING installed beforethe walloven isinstalled. Seeillustration(Electrical W iring (WALLOVENINSTALLEDBELOW30" OOOKTOP) Information- page 4; figure6) for recommended electricalsupplysource locations.
  • Page 5: Pressure Testing

    ALTERNATIVEPIPING METHODSTO CONNECT APPLIANCETO GAS SUPPLY A TRAINEDSERVICEMAN OR GASAPPLIANCEINSTALLER MUST CAUTION: Do not attemptto attach the flexible connectordirectlyto an MAKETHEGASSUPPLY CONNECTION. L eaktestingofthe appliance externalpipethread.Connectionrequiresflare union adapters. shall be conductedby the installeraccordingto the instructions given. IMPORTANT Unlessprohibitedby localcodesor ordinances,a newA.G.A. - Certified, Apply a non-corrosive leak detectionfluidto all joints and fittings in the flexible metalapplianceconnectormay be usedto connectthis appliance gas connectionbetweenthe supply line shut-offvalve and the range.
  • Page 6: Electricalwiring Information

    ELECTRICALWIRING INFORMATION Thisapplianceis equipped witha grounded t ypepower cord. A grounded and, if necessary, throughthe slatssupporting the shelf.Theclearance outlet mustbeprovided, tt is recommended, forconvenience, theoutlet be holeshouldbe locatedas nearas practical t o the rearof the shelf and located (with reference tofigure6) as inA or B, below: (ifthe ovenis model W 30XXX)asnearaspractical t othe left rearcorner.
  • Page 7 CONVERTINGAPPLIANCE FOR USE INSTALLATIONOF LP ORIFICE SPUDS WITH LP GAS 4 BURNER MODEL (30" WIDE) WARNING Propaneconversionisto be performed by a JENN-AIRAUTHORIZED SERVICER (or other qualified agency) in accordance with the manufacturer'sinstructionsand all codes and requirementsof the authorityhavingjurisdiction.Failureto followinstructions couldresultin seriousinjuryor property damage, T he qualifiedagencyperforming this workassumesresponsibility for this conversion.
  • Page 8 B. Invert cap in appliancepressureregulator 3. Inserta slender,thin-bladescrewdriver into the recessat center of (Seefigures 10 and 11.) valve stem and engagebladewith slot in adjustingscrew. Withtheapplianceinstalled, theapplianceregulatorshouldbelocated asshownin figure 3 or4. Identifythetypeofapplianceregulatoron the 4. Turn centerstemadjustingscrewto set flame size. unitand follow the instructions inthe appropriateillustration..
  • Page 9: Natural Gas

    TO CONVERTAPPLIANCE FOR USE WITH INSTALLATIONOF NATURAL GAS NATURALGAS ORIFICE SPUDS WARNING 4 BURNER MODEL (30" Electrical power and gas must be turnedoff prior to conversion. If this appliancehas been convertedfor use with LP gas, each of the following modificationsmust be performedto convertthe unit back to naturalgas.
  • Page 10: Burnerignition And Auto-Reignition

    BURNERIGNITION AND AUTO-REIGNITION TOP GRATE REPLACEMENT This applianceis equippedfor electronicauto-reignitionby means of a The topgrateson this cooktophaveundersideprojectionlugsdesignedto spark igniter l ocatedat the rearof each burner.The burnersaredesigned nestin matching depressions inthe spillovertrays.Duringgrateplacement tolightat anyvalverotation that admitssufficientgasflowto supportaflame alwaysposition gratesto makethis engagement. C orrectindexing o f grates andto automaticallyretight f ollowinga loss offlame dueto a draft or other aboveburnerportswill preservethe grates'appearanceand help assure adversecondition.This feature is providedas a convenienceand is not...

This manual is also suitable for:

Ccg2523Jgc7430Jgc7536

Table of Contents