Door swing change

The door can be attached to open with hinges on
the left or right using new hinge brackets shipped
loose in the ice bin. Retain all screws for re-use.
To change:
1. Remove innermost
screw holding each
hinge to cabinet, loosen
the other.
2. Slide hinges to the side
and remove door from
cabinet. Remove
screws loosened in step
1 from both cross
braces.
3. Remove two screws securing top panel to
back, pull top panel back and remove from
cabinet.
4. Remove two screws at
the top and lift the
upper bracket out of
the cabinet. Replace
with the one supplied
loose with the machine.
Fasten it to the cabinet
using the original
screws.
5. Return the top panel to the cabinet and fasten
it with the original screws.
6. Remove kickplate and front service panel.
7. Remove two front screws and two bottom
screws holding the bottom door bracket to the
cabinet.
Screw Below
8. Replace the bracket with the one supplied
loose with the machine. Secure it using the
original screws.
9. Remove the upper hinge and move it to the
door's opposite side, bottom location. Secure
using the original screws.
Note: If door panel is attached, it must be removed
to access hinge screws.
10. Remove the original lower hinge and move it to
the door's opposite side, upper location.
Secure using the original screws.
11. Install a screw removed in step 2 in outermost
hole of upper and lower cross braces.
12. Attach the door to the cabinet using the original
screws.
Upper
13. Return kickplate and front service panel to their
Bracket
original positions and attach to the cabinet
using the original screws.
Installation Notes
Built In Situations: If a finished floor is to be
installed in the area after the ice machine has been
built in, shims the expected thickness of the floor
should be installed under the unit to keep the
machine level with the planned floor level.
Installations on a slab: Use a pump model and
pump the water to the point of drainage. Pump
models will pump 1 story (10 feet) high.
Installations over a crawl space or basement:
Either gravity drain or pump model units may be
used, if there is not enough room behind the
machine for a drain/waste receptacle, the drain will
have to be below the floor.
Note: When installed in a corner, the door swing
may be limited due to handle contact with the wall
or cabinet face.