Door swing change

The door can be attached to open with hinges on
the left or right using new brackets shipped loose in
the ice bin. Retain all screws for re-use.
To change:
1. Remove innermost
screw holding each
hinge to cabinet, loosen
the other.
2. Slide hinges to the side
and remove door from
cabinet. Remove
screws loosened in step
1 from both hinge brackets.
3. Remove two screws securing top panel to
back, pull top panel back and remove from
cabinet.
4. Remove two screws at
the top and lift the door
hinge bracket out of the
cabinet. Replace with the
one supplied loose with
the machine. Fasten it to
the cabinet using the
original screws.
5. Return the top panel to the cabinet and fasten
it with the original screws.
6. Remove kickplate and front service panel.
7. Remove two front screws and two bottom
screws holding the bottom cross brace to the
cabinet. Replace the brace with the one
supplied loose with the machine. Secure it
using the original screws.
Screw Below
8. Remove the upper hinge and move it to the
door's opposite side, bottom location. Secure
using the original screws.
9. Remove the original lower hinge and move it to
the door's opposite side, upper location.
Secure using the original screws.
10. Install a screw removed in step 2 in outermost
hole of upper and lower cross braces.
11. Attach the door to the cabinet using the original
screws.
12. Return kickplate and front service panel to their
original positions and attach to the cabinet
using the original screws.
Installation Notes
Built In Situations: If a finished floor is to be
Door Hinge
installed in the area after the ice machine has been
Bracket
built in, shims the expected thickness of the floor
should be installed under the unit to keep the
machine level with the planned floor level.
Installations on a slab: Use a pump model and
pump the water to the point of drainage. Pump
models will pump 1 story (10 feet) high.
Installations over a crawl space or basement:
Either gravity drain or pump model units may be
used, if there is not enough room behind the
machine for a drain/waste receptacle, the drain will
have to be below the floor.
Note: When installed in a corner, the door swing
may be limited due to handle contact with the wall
or cabinet face.
June 2008