Specifications - Scotsman SCCG50 Enodis Installation And User Manual

Residential ice machine
Hide thumbs Also See for SCCG50 Enodis:
Table of Contents

Advertisement

Specifications

This ice machine is designed to be used indoors, in
a controlled environment. It can be used in a wide
variety of environmental conditions, but there are
limits. Use outside of the listed limitations is misuse
and will void the warranty.
Air temperature limits:
The ice machine will operate adequately within the
limits, but functions best in temperatures between
70 and 80 degrees F.
Minimum – 50 degrees F. (10
Maximum – 100 degrees F. (38
Water temperature limits:
Minimum – 40 degrees F. (4.5
Maximum – 100 degrees F. (38
Water pressure limits:
Minimum – 20 psi (1.4 bar)
Maximum – 80 psi (5.5 bar)
Because the ice machine is making a food product,
the water supply to the ice machine must be
potable, or fit for human consumption.
Electrical voltage limits:
Minimum - 104 volts
Maximum – 126 volts
Models
There are six models, all air cooled:
SCCP50M-1WU – Pump model, white cabinet
SCCG50M-1WU – Gravity drain model, white cabinet
SCCP50M-1BU – Pump model, black cabinet
SCCG50M-1BU – Gravity drain model, black cabinet
SCCP50M-1SU – Pump model, stainless cabinet
SCCG50M-1SU – Gravity drain model, stainless cabinet
Cabinet Dimensions
Width
Depth, w/out door panel
14 7/8"
o
C)
o
C)
o
C)
o
C)
Depth, with door panel, handle adds 1 5/8"
22"
Installation and User's Manual
Options:
Door Panels: Finished door panels are available
from Scotsman for attachment to the machine, or a
custom panel can be made. The panel kits are:
Kit Number Panel Finish
KDFW
White
KDFWS
White
KDFB
Black
KDFBS
Black
KDFS
Stainless Steel
Kickplate Extension: In some situations the leg
levelers will be extended enough to become visible.
A kit to extend the kickplate over the legs is KKPF.
Cabinet Stability: In some free standing
installations it may be prudent to add a bracket that
secures the back of the cabinet to a wall. That kit
number is KATB.
Drain Conversion: A gravity drain model can be
converted to a drain pump model by installing a
drain pump kit. The drain pump kit consists of a
drain pump, wiring harness and associated tubing.
The part number is A39462-021.
Warranty Information
Warranty information is supplied separately from
this manual. Refer to it for coverage. In general, the
warranty covers defects in materials or
workmanship and does not cover corrections of
installation errors or maintenance.
22 3/4"
July 2008
Page 2
SCCG50 & SCCP50
Handle Finish
White
Stainless Steel
Black
Stainless Steel
Stainless Steel
Height
33 3/8" to 34 3/8"