Indicator Led - Denso GT10B-SM User Manual

Bar code handy scanner
Hide thumbs Also See for GT10B-SM:
Table of Contents

Advertisement

9.2

Indicator LED

The indicator LED lights or flashes in blue, green, red or orange to indicate the scanner status as described below.
Lights in blue when:
• a read of a bar code is successfully complete (Note that when the auto sensing mode switching function* is enabled,
the indicator LED lights in green.),
• the "Start setting" or "End setting" bar code symbol is read from the bar-coded parameter menu (given in Chapter
12),
• bar code data read matches the master data in the data verification mode,
• the auto sensing mode switching function* has switched the scanner to the currently selected trigger switch
operating mode, or
• switched to the trigger switch operating mode using the continuous reading mode switching function.
Lights in green when:
• a processing started by magic key control has completed,
• the scanner is ready to register master data in the data verification mode, or
• the scanner has read a bar code (except a master bar code for data verification) successfully with the auto sensing
mode switching function* being enabled.
Lights in red when:
• a check digit error has occurred,
• a bar code read has the wrong number of digits,
• bar code data read does not match the master data in the data verification mode,
• a master bar code read has the wrong number of digits in registration of master data,
• the data retransfer function failed to transfer data, or
• an editing error has occurred in the specified data editing, resulting in no transfer.
Flashes red when:
• no master data has been registered in the data verification mode.
Lights in orange when:
• the auto sensing mode switching function* has switched the scanner to the auto sensing mode, or
• switched to the continuous reading mode using the continuous reading mode switching function.
The indicator LED can be disabled with the bar-coded parameter menu or configuration software (ScannerSetting). In
any of the following cases, however, the indicator LED comes on regardless of the current LED setting:
- When the scanner is being customized with the bar-coded parameter menu (Chapter 12).
- When the configuration software (ScannerSetting) starts up or accepts any new setting.
- When a batch-process bar code symbol is read.
- When a master bar code is being registered or the registration is complete.
- When any error has occurred during entry of a master bar code.
- When the verification result is a mismatch, the scanner is locked, or no master data has been registered in the data
verification mode.
- When data retransfer with the magic key is complete or the previously sent data is not available at the time of data
retransfer.
- When specific character transfer with the magic key is complete.
- When a hardware error has occurred.
- When the scanner has failed to save setting.
*For the auto sensing mode switching function assigned to the magic key, refer to Chapter 6.
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gt11b-smGt10b-lm

Table of Contents