Optional Blower Installation Instructions - Empire Comfort Systems VFP30CA30 Series Installation Instructions And Owner's Manual

Cast iron unvented room heater
Table of Contents

Advertisement

oPtionaL BLoWeR instaLLation instRUctions

Installing Optional CIB3 Blower
1. Loosen, but do not remove, four (4) hex-head screws located
on the exterior, bottom of the appliance.
2. Position the blower assembly at the rear of the appliance. The
blower assembly has four (4) keyholes for attachment to the
exterior, bottom of the appliance.
3. Place the large diameter holes in the keyholes over and behind
the four (4) hex-head screws that were loosened in Step 1.
Push inward on the blower assembly to lock the keyholes into
position behind the screws. Tighten four (4) hex-head screws to
secure blower assembly to exterior, bottom of the appliance.
4. Remove wire channel-left from appliance by removing (2)
10 x 1/2" screws on left side of the appliance. Note: Some
units require a new wire channel. If Rheostat mounting holes
are missing from part removed from unit, discard wire channel
removed from unit and continue installation with appropriate
wire channel shipped with blower. See Figure 23.
5. Route fan control wires through rectangular notch on wire
channel - left.
6. Attach 1/4" push-on terminal from blue wire on the fan control
to the AUTO (top) tab on the switch.
7. Attach 1/4" push-on terminal from black wire to the OFF
(middle) tab on the switch.
8. Attach 1/4" push-on terminal from white wire on the fan control
to the ON (bottom) tab on the switch.
9. Insert AUTO/OFF/ON switch into rectangular notch on wire
channel - left.
(DV) MODELS
(VF) MODELS
WIRE CHANNEL - LEFT
26563-0-0410
10. Install rheostat through hole in wire channel and align small
11. Use an 11/16" wrench to tighten rheostat nut on stationary
12. Push rheostat knob onto knob stem until fully seated.
13. Bend the fan control tab, located on the left side of the back
14. Attach fan control with bracket onto rear cover with
15. Route wires from fan control and ON/OFF/REMOTE switch
16. Attach wire channel to channel divider with two (2) 10 x 1/2"
17. Installation of optional CIB3 blower is completed.
Fan Control
The fan control is a non-adjustable automatic type The fan control
will require between 5 and 10 minutes of main burner operation
before the fan control "closes" and activates the blower. The blower
will continue to run between 5 and 10 minutes after the main
burner shuts off, before the fan control "opens" and deactivates
the blower.
FAN CONTROL TAB
BLOWER ASSEMBLY
Figure 23
tab with small hole.
portion of knob stem of the rheostat. Note: Nut is self-tapping
and can be started at an angle.
of the unit, inward toward the unit. See Figure 23. Be sure tab
is bent at least 90 degrees to allow fan control bracket to slide
into slot.
two (2) 10 x 1/2" screws provided in hardware package.
within wire channel.
screws from Step 4.
AUTO/OFF/ON SWITCH
FAN CONTROL
KNOB
RHEOSTAT
NUT
WIRE CHANNEL - LEFT
Page 25