Clearances - Empire Comfort Systems VFP30CA30 Series Installation Instructions And Owner's Manual

Cast iron unvented room heater
Table of Contents

Advertisement

Clearances (Figures 2, 3, and 4)
When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Top of appliance (ceiling)
Rear Wall
Side Wall
Heater Corners (45° angle) to Wall
Floor
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
Installation on Rugs and Tile
This appliance must be installed on a flat, solid, continuous surface
(e.g. wood, metal, concrete). This may be the floor, or it may be
raised up on a platform to enhance its visual impact. The appli-
ance may be installed on carpeting, vinyl, wood flooring or other
combustible material.
6" (153mm) TO SIDE WALL
OR COMBUSTIBLE
MATERIAL
26563-0-0410

CLEARANCES

36 inches
2 inches
6 inches
4 inches
0 inches
36" (91cm) TO CEILING OR
HORIZONTAL PROJECTION
ABOVE APPLIANCE
Figure 2
4" (102mm) HEATER CORNERS
TO SIDE WALL
NOTE: HEATER INSTALLED AT
45° ANGLE IN CORNER
Figure 3
2" (51mm) TO COMBUSTIBLE MATERIAL
Figure 4
4"
(102mm)
Page 9