Ensuring the earth continuity
If the unit is fitted in a bathroom, to conform with the current BS.7671 (formally IEE regulations),
the units earth continuity conductor must be effectively connected to ALL exposed metal parts of
ALL other appliances in the room.
CHECKING FOR LEAKS
Let the water run through the unit for a few seconds. Check that no pipe joints leak.
ADJUSTING THE SERVICE VALVE
Turn the service valve on, then:-
If the unit is to supply a basin,
- turn on the hot water tap fully at the basin.
- adjust the service valve until the water comes out of the tap at the required temperature.
- check that the unit works correctly when the basin tap is closed and then opened again:
if not, adjust the service valve slightly.
If the unit is to supply a shower,
- turn the hot water tap on the mixer unit fully on.
- turn the service valve anti-clockwise until the neon light goes out, then turn it back until the
neon just comes on.
- check the water temperature at the handset and, if necessary, turn the cold tap on and adjust
to get the desired shower temperature.
WARNING: IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER,
YOU MUST CLEAN THE SHOWER HANDSET REGULARLY.
All water contains particles of lime-scale, which build up in the shower handset and unit reducing the
performance.
It is therefore important to clean the shower handset by regularly dipping it in a suitable descaling
solution. The frequency of this will depend on water hardness and experience.
Explain to the user that when the unit is used, the hot water tap should be turned fully
on so that the unit will operate correctly.

COMMISSIONING YOUR IL095