SERVICING INSTRUCTIONS (continued)
WARNING
Electric Shock Hazard
Disconnect Water-Max™
from electrical power before removing
any panel or cover.
TOOLS REQUIRED:
#2 Phillips Screwdriver
Container to hold fasteners
Flat Blade Screwdriver
Needle Nose Pliers
11/32" Nut Driver
CONTACTOR
Repair time not to exceed 0.5 hour
A. Preparation
1. Disconnect Water-Max™ from electrical power.
2. Shut off water supply to Water-Max™.
B. Removal
1. Remove top cover and wrap (see page 28)
2. Note position of wires on contactor.
3. Disconnect old contactor:
a. Disconnect wires from contactor.
b. Remove two self-locking nuts holding contactor to
shelf. Lift old contactor off of studs; discard old
contactor.
C. Installation
1. Note orientation of contactor. The two coil screws point
toward the left.
2. Slide contactor mounting holes over studs. Secure with
self-locking nuts.
3. Connect wires to the contactor. Be sure connectors for
12 ga. wires are tight.
See drawing at left for configuration.
4. Reinstall top cover and wrap.
D. Return Unit to Service
1. Turn water supply on and check for leaks.
2. Connect Water-Max™ to electrical power and test for
proper operation.