Schlage AD-400 Instruction Manual

Schlage AD-400 Instruction Manual

Adaptable series networked wireless lock user guide
Hide thumbs Also See for AD-400:

Advertisement

P516-127
AD-400
AD-401
NETWORKED WIRELESS LOCK USER GUIDE
INSTRUCTIONS FOR ADAPTABLE SERIES NETWORKED WIRELESS LOCKS
Para el idioma español, navegue hacia www.schlage.com/support.
Pour la portion française, veuillez consulter le site www.schlage.com/support.

Advertisement

Table of Contents
loading

Summary of Contents for Schlage AD-400

  • Page 1 P516-127 AD-400 AD-401 NETWORKED WIRELESS LOCK USER GUIDE INSTRUCTIONS FOR ADAPTABLE SERIES NETWORKED WIRELESS LOCKS Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support.
  • Page 2: Table Of Contents

    AD-400 /AD-401 Networked Wireless Lock User Guide CONTENTS Overview ............................3 Getting Started ..........................4 Schlage Utility Software (SUS) ...................... 4 Optional Inside Push Button (IPB) ....................5 User Management ......................... 5 Construction Access Mode ......................6 Create the Master Construction Credential - Locks with Card Readers ........6 Add Construction Access Mode User Credentials - Locks with Card Readers ......
  • Page 3: Overview

    • The AD-400/AD-401 communicates with the PIM400 via RF (radio frequency). • The AD-400/AD-401 may be battery powered or connected to external power using a UL294 or ULC S318/ULC S319 listed power supply. See Batteries on page 11 or External Power Supply on page 12 for more information.
  • Page 4: Getting Started

    When in a low battery condition the lock may operate but not have suffi cient power to communicate with the SUS. When intitiating SUS communication, the Schlage button will light solid red for one second to indicate power is not suffi cient. If this should occur, change the batteries immediately.
  • Page 5: Optional Inside Push Button (Ipb)

    The IPB may be used to communicate a lock/unlock request or be completely ignored by the network software. • AD-400 IPB activity will only be reported to control systems connected to a PIM400-485 with a RS-485 connection.
  • Page 6: Construction Access Mode

    Add Construction Access Mode User Credentials - Locks with Card Readers 1. Present the Master Construction Credential to the lock. The Schlage button will light solid green for 20 seconds. 2. Present the user credential to be added within twenty (20) seconds. The user credential will be added to the lock database.
  • Page 7: Link To A Pim400

    PIM400 (example: 3 blinks and beeps = channel 3). 9. If the link fails, the Schlage button will blink red three (3) times and fi ve (5) short beeps will sound. The PIM400 will remain in link mode. Carefully repeat steps 1-8 above. If repeated LINK attempts fail, change the frequency channel of the PIM400 and/or move the PIM400, then repeat steps 3-7.
  • Page 8: Test Lock Operation

    3. For locks with a card reader, present a credential to the reader. The lock will beep and the left side of the Schlage button will blink red one time. When the lock is in Factory Default mode, no credentials are accepted and the lock will respond with one red blink indicating the lock is not linked with the PIM400.
  • Page 9: Reset To Factory Default Settings

    4. Press and release the inside push button (IPB) three (3) times within 10 seconds. One beep will sound and one red blink will occur with each press. 5. The Schlage button and IPB will both light green for one second and a one-second beep will sound to confi rm that the lock has been reset.
  • Page 10: Communication Properties

    When communication fails between the AD-400/AD-401 and the PIM400, the lock will go into Communication Failure Mode. If the ACP or the PIM400 lose power, the AD-400/AD-401 can lock, unlock, remain as-is, or allow valid access without communicating to the ACP or the PIM400. This mode can be confi...
  • Page 11: Batteries

    When in a low battery condition the lock may operate but not have suffi cient power to communicate with the SUS. When intitiating SUS communication, the Schlage button will light solid red for one second to indicate power is not suffi cient. If this should occur, change the batteries immediately.
  • Page 12: Battery Failure Modes

    The AD-400/AD-401 may be connected to external power using a UL294 listed Power Supply for UL installations, and a power supply that complies with CAN/UL-S318 or CAN/ULC-S319 for cUL installations. The power supply must be capable of sourcing at least 250 mA @ 12 or 24 VDC (Schlage PS902, PS904, PS906).
  • Page 13: Led And Beep Reference

    AD-400 /AD-401 Networked Wireless Lock User Guide LED AND BEEP REFERENCE The beep indicator may be enabled or disabled using the SUS. See the SUS User Guide for more information. Schlage Button Action LEDs Beeps Extended (Toggle) unlock 2 Green...
  • Page 14: Troubleshooting

    AD-400 /AD-401 Networked Wireless Lock User Guide TROUBLESHOOTING Problem Possible Cause Solution The lock beeper does The reader may not be Check that the reader is fully seated into not sound and the properly seated into the front the front escutcheon.
  • Page 15 AD-400 /AD-401 Networked Wireless Lock User Guide Problem Possible Cause Solution The reader is not The through hole ribbon Check that the through hole ribbon cable working. cable may be pinched. is not pinched. The Smart card is not The Smart card default of Change the Smart card format using reading.
  • Page 16: Fcc/Ic Statements

    This transceiver is to be professionally installed in the end product by Ingersoll Rand, and not by a third party. The Ingersoll Rand AD-400 900 MHz Communication Board Module will not be sold to third parties via retail, general public or mail order. In the case of a repair, the transceiver will be replaced by a professional Installer.