H1/3 WHITE/BLUE (-) remote start activation input
This input comes from the factory set to 2 activation pulses. This means that it is necessary to have 2 consecu-
tive ground pulses on the white/blue wire for the remote start to activate or to deactivate. The same holds true
for the remote control activation when set to a two pulse setting it is necessary to press the
for the remote start to activate or deactivate.
NOTE: When the activation pulse count can be programmed to 1, 2, or 3 pulses when changed it
will affect both activation inputs; the White/Blue wire and the remote control activation.
H1/4 BLACK /WHITE (-) 200 mA domelight supervision output
Connect this wire to the optional domelight supervision relay as shown below:
IMPORTANT! This output is only intended to drive a relay. It cannot be connected directly to the
domelight circuit because the output cannot support the current draw of one or more light bulbs.
H1/6 BLUE second unlock
This output is used for progressive door unlock. A progressive unlock system unlocks the driver's door when the-
unlock (disarm) button is pressed and unlocks the passenger doors if the unlock (disarm) button is pressed again
14
button twice