Wall Switch Installation For Fan (Optional); Junction Box Installation - Heatilator CB4236IR Owner's Manual

B-vent gas appliance
Hide thumbs Also See for Heatilator CB4236IR:
Table of Contents

Advertisement

D. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
Remove the cover plate located on the outer shell - right
side (see Figure 10.2).
Install the supplied Romex™ connector in the cover
plate.
Feed the necessary length of wire through the
connector.
Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the INSIDE of the appli-
ance:
Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 10.2).
Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
Feed the necessary length of wire through the
connector.
Make all necessary wire connections to the junction
box/receptacle and reassemble the junction box/
receptacle to the outer shell.
E. Wall Switch Installation for Fan (Op-
tional)
If the box is being wired to a wall mounted switch
for use with a fan (See Figure 10.3):
The power supply for the appliance must be
brought into a switch box.
The power can then be supplied from the switch
box to the appliance using a minimum of 14-3
with ground wire.
At the switch box connect the black (hot) wire
and red (switch leg) wire to the wall switch as
shown.
At the appliance connect the black (hot), white
(neutral) and green (ground) wires to the junction
box as shown.
Add a 1/4 in. insulated female connector to
the red (switch leg) wire, route it through the
knockout in the face of the junction box, and
connect to the top fan switch connector (1/4 in.
male) as shown.
Figure 10.3 Fan Control Switch Wiring
Heatilator • Caliber BV Series • 4040-262 Rev F • 05/07
Figure 10.2 Junction Box Detail
Minimum 14-3 AWG
with Ground
Red
Black
White
Junction Box
Red
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
Note: Do NOT wire 110
VAC to wall switch.
Black
White
Green
Green
Switch Box
Knockout
Switch
Power
Supply
Wires
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cb4842ir

Table of Contents