Chauvet Scan 300 RGB EU User Manual page 7

Scorpion scan 300 rgb eu
Table of Contents

Advertisement

Available languages

Available languages

3. S
ETUP
AC Power
Fuse
Replacement
Mounting
Orientation
Scorpion Scan 300 RGB EU User Manual (Rev. 1 ML)
The Scorpion™ Scan 300 RBG EU has an auto-ranging power supply and it can work
with an input voltage range of 100~240 VAC, 50/60 Hz.
To determine the product's power requirements (circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product's back panel, or
refer to the product's specifications chart. The listed current rating indicates the
product's average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0~100% switch.
If the power input cord that came with your product has no plug or you need to change
the plug, use the table to wire the new plug:
Cable(EU)
Brown
Light blue
Yellow/Green
Disconnect the product from power before replacing the fuse.
1.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2.
Pry the fuse holder out of the housing.
3.
Remove the blown fuse from the holder and replace with a fuse of the exact same
type and rating.
4.
Insert the fuse holder back in place and reconnect power.
Spare fuse holder
(inside safety cap)
The product does not ship with a spare fuse; however, the safety cap has room
for a spare.
Always replace a blown fuse with the same type and rating.
CAUTION! Adhere to the respective national legal requirements for laser use
during mounting! Mounting must only be carried out by qualified persons! Before
mounting, read and follow ALL the safety recommendations in this manual.
The Scorpion™ Scan 300 RBG EU is designed for overhead mounting. Make sure
adequate ventilation is provided around the product. Be sure to use a suitable hanging
clamp and safety cable. Accessories needed for safe and effective mounting are
available from your local lighting distributor.
Pin
International
Live
L
Neutral
N
Earth
Installed fuse
(held by plastic clip)
Safety cap
7