Telephone Line Fail Options; Dialler Options 1; Dialler Options 2; Dialler Options 3 (V1.04+) - Bosch CC488 Quick Reference Manual

Solution ultima 880
Hide thumbs Also See for CC488:
Table of Contents

Advertisement

CC488 | Quick Reference Guide | 2.0 Programming Parameters
2.1.17

Telephone Line Fail Options

Location
176
Default
0
1
Display FAULT Indicator when telephone line fails
2
Sound alarm when system is armed
4
Sound alarm when system is disarmed
Options 2 and 4 must be used in conjunction with Option
1 (for example, program 1, 3, 5, or 7)
2.1.18

Dialler Options 1

Location
177
1
Dialler reporting functions allowed
2
Remote arming by telephone allowed
4
Answering machine bypass only when armed
8
Use Bell 103 for FSK format (Disabled = CCITT V21)
2.1.19

Dialler Options 2

Location
178
Default
0
1
Open/Close Reports only if previous alarm
2
Open/Close Reports for STAY Mode 1 and STAY
Mode 2
4
Delay siren until transmission complete
8
Extend handshake wait time from 30 to 55 sec.
2.1.20
Dialler Options 3
Location
179
0
Default
1
Set DTMP dialling pulses to 1 digit/sec.
2
Lockout telephone line fail alarm (V1.03+)
4
Change Decadic dialling to 60/40
8
Reserved
2.1.21

Dialler Options 3 (V1.04+)

Location
179
1
Set DTMP dialling pulses to 1 digit/sec.
2
Lockout telephone line fail alarm (V1.03+)
4
Change Decadic dialling to 60/40
8
External modem module (CC811) required for FSK
(V1.09+)
2.1.22

Alarm Link Options

Location
180
1
Upload/download allowed
2
Call back phone number required for upload/download
4
Exit upload/download connection on alarm
8
External modem module (CC811) required for alarm link
2.2

Installer Code

Location
181 to 184
Bosch Security Systems | 6/04 | 4998152446B
Location
Default
181
1
182
2
183
3
184
4
2.3

User Code Programming

2.3.1

User Codes

Location
185 to 264
Location
User #01
185
186
187
188
189 (Authority Level)
User #02
190 to 193
194
User #03
195 to 198
199 (Authority Level)
User #04
200 to 203
204 (Authority Level)
User #05
205 to 208
209 (Authority Level)
User #06
210 to 213
214 (Authority Level)
User #07
215 to 218
219 (Authority Level)
User #08
220
221 to 223
224 (Authority Level)
RF User #09
225 to 228
229 (Authority Level)
RF User #10
230 to 233
234 (Authority Level)
RF User #11
235 to 238
239 (Authority Level)
RF User #12
240 to 243
244 (Authority Level)
RF User #13
245 to 248
249 (Authority Level)
RF User #14
250 to 253
254 (Authority Level)
RF User #15
255 to 258
259 (Authority Level)
RF User #16
260 to 263
264 (Authority Level)
2.3.2

Authority Levels

Authority
Description
Levels
0
Arm/Disarm
1
Arm Only
2
Arm/Disarm and Open/Close Reports
3
Arm Only and Close Reports
4
Arm/Disarm and Code Required to Isolate
6
Arm/Disarm and Open/Close Reports and Code
Required to Isolate
8
Master Code and Arm/Disarm
10
Master Code and Arm/Disarm and Open/Close
Reports
12
Master Code and Arm/Disarm and Code
Required to Isolate
14
Master Code and Arm/Disarm and Code
Required to Isolate and Open/Close Reports
EN | 12
Default
2
5
8
0
10
15
2
15
2
15
2
15
2
15
2
15
2
0
15
3
15
2
15
2
15
2
15
2
15
2
15
2
15
2
15
2