Harman Stove Company XXV Installation & Operating Manual page 7

Pellet stove
Hide thumbs Also See for XXV:
Table of Contents

Advertisement

Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect
the circuit board.) Also be sure that the polarity of the outlet
that the stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft meter. Turn the
Feed Adjuster dial to "Test". Record the first reading. Connect
flue pipe to stove and be sure all doors and windows in the
home are closed. Record the second draft reading_______.
If the second reading is more than .05" lower than the first
reading, check for possible restrictions or the need for outside
air (see page 10). For more information on the draft test
procedure, refer to Page 17.
Mobile home installation
When installing this unit in a mobile home several requirements
must be followed (Reference HUD Regulation #24CFR3280):
1. The unit must be bolted to the floor. This can be done by
using clips (part # 2-00-677110B) and 1/4" lag screws.
2. The unit must be connected to outside air. See page 10.
3. Floor protection and clearances must be followed as
shown above.
4. Unit must be grounded to the metal frame of the mobile
home.
5. Chimney must meet requirements of CAN/ULC-S629,
Standard for 650°C Factory Built Chimneys. Follow
Manufacturer's guidelines concerning height and
clearances to combustibles. Use the same manufacturer's
components to provide an effective vapor barrier where
the chimney or other component penetrates to the the
exterior of the mobile home. dO nOt MiX cOMPOnentS
FrOM diFFerent ManuFacturerS. The top section
of chimney and the chimney cap must be removable to a
maximum height of 13.5' for transport of the mobile home.
CAUTION: This appliance must be vented to the outside.
cautiOn
t h e S t r u c t u r a l i n t e g r i t Y O F t h e
ManuFactured hOMe FlOOr, wall, and ceiling/
rOOF MuSt be Maintained.
warning
dO nOt inStall in a SleePing rOOM.
3-90-00684R22_04/13
installation
Fig. 5: Optional Top Vent Pipe Clearances
18"/
457mm
6"/152mm
from pipe to
wall
XXV Pellet Stove
4"/102mm
from back of
top flue vent
to wall
7

Advertisement

Table of Contents
loading

Table of Contents