Chapter 10 Appendix; When The Power Led Blinks - Buffalo LS410D User Manual

Ls400 series
Hide thumbs Also See for LS410D:
Table of Contents

Advertisement

Chapter 10 Appendix

When the Power LED Blinks

White
The power LED will blink white during bootup or shutdown.
Red
If there is an error, the power LED will blink red. The pattern of the blink gives the error code. You can also see any errors
in NAS Navigator2.
Place of Error Code
10s Place of Error Code
1s Place of Error Code
Error Code
E07
E11
E12
E13
E14
E15
E16
Status
The LED flashes for 1.0 second every 0.3 seconds. This gives the tens place of
the error code.
The LED flashes for 0.5 seconds every 0.3 seconds.
Description
The firmware is corrupted.
An error occurred in the fan speed.
A rise in the system temperature may
have exceeded the allowable safety value.
An error occurred in the RAID array. The
LinkStation is in degraded mode.
RAID array X cannot be mounted.
The bad sectors have reached a
dangerous level.
Unable to find hard drive X.
Corrective Action
Contact Buffalo technical support for
assistance.
Check that foreign objects or dust are
clogging the fan. If any foreign objects
or dust are found, use a pair of tweezers,
air duster, or other tool to remove them.
If the error is displayed again, contact
Buffalo technical support for assistance.
Do not place objects in the area
around the LinkStation. Also, move the
LinkStation to a cool location.
Replace the defective drive whose NAS
Navigator2 or Settings shows error.
Rebuild the RAID array after replacing the
drive and rebooting the LinkStation.
Run the RAID array disk check in Settings.
Replace the defective drive whose NAS
Navigator2 or Settings shows error.
Hard drive X may be disconnected or may
be failed. After shutting down, reinstall
the hard drive.
83