Dimensions & Specifications - Garland MASTER Installation And Operation Manual

Gas convection oven
Hide thumbs Also See for MASTER:
Table of Contents

Advertisement

DIMENSIONS & SPECIFICATIONS
Int. Dimensions :In (mm)
Single-Deck
Models
Standard Depth 29 (736) 24 (610) 24 (610) 38 (965) 57-1/2 (1461)
Deep Depth
29 (736) 24 (610) 28 (711) 38 (965) 57-1/2 (1461)
Int. Dimensions: In (mm)
Double-Deck
Models
Standard Depth
29 (736) 24 (610) 24 (610) 38 (965) 70-1/2 (1791)
Deep Depth
29 (736) 24 (610) 28 (711) 38 (965) 70-1/2 (1791)
*Height with or without standard casters. Height with low profile casters (double deck) is 68-1/2" (1740mm).
Models
Single Deck
Double Deck
3/4" N.PT.
GAS INLET
7-3/4"
[197mm]
3/4"
[19mm]
FLUE: 2-3/8" x 5"
[60mm x 127mm]
D
(includes
fan motor)
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
H
25-3/8"
[645mm]
SINGLE DECK
FR ONT VIEW
Gas Input ratings shown here are for installations up to 2,000-ft. (610m) above sea level. Specify altitudes over 2,000 ft.
Commercial cooking equipment requires an adequate ventilation system. For additional information, refer to the National Fire
Protection Association's standard NFPA96, "Vapor Removal from Cooking Equipment." (NOTE: For North America only)
Please specify gas type when ordering.
Page 4
W
H
D
W
H
D
Input Ratings, Nat & Pro
BTU/hr
kW Equiv.
60,000
17. 6
120,000
35.2
2"
[51mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
TOP VIEW
38"
[965mm]
3/4" REAR
GAS INLET
54-9/16"
[1386mm]
34"
[864mm]
Ext. Dimensions: In (mm)
W
H *
41-1/4(1048)
44-1/2(1130)
Ext. Dimensions: In (mm)
W
H *
41-1/4(1048)
44-1/2(1130)
Electrical Specifications
Gas Inlet
120V/1Ph.
(1 )@ 3/4" NPT
(1)@9.8A
(1 )@1" NPT
(2)@9.8A
1-1/4"
[32mm]
32-1/8"
[816mm]
H
32-1/8"
[816mm]
6-1/4"
[159mm]
Installation Notes:
Combustable Wall Clear-
ances:
Sides: 1" (25mm)
Back: 3" (76mm)
Entry Clearance:
Crated: 47" (1194mm)
Uncrated: 32-1/2" (826mm)
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V 3/4 HP, 2-speed motor; 1140 and 1725 rpm 60Hz
3. (240V units) 200-240V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60Hz
4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug.
5. Garland recommends a separate 15 AMP circuit for each 120V unit.
Ship Wt
Ship Dim.
D
Lbs/kg
Cubic Ft.
515/230
64
545/245
64
Ship Wt.
Ship Dim.
D
2@Lbs/kg
Cubic Ft.
1030/465
128
1090/490
128
240V/1Ph.
(1)@ 5.2A
(2)@ 5.2A
1" REAR
GAS INLET
32-1/8"
[816mm]
32-1/8"
[816mm]
35-7/16"
[900mm]
14-3/4"
[375mm]
DOUBLE DECK
FR ONT VIEW
Operating Pressure:
Natural: 4." WC (10 mbar)
Propane: 10" WC (25 mbar)
Max 13.8" WC @ 70°F (21°C)
NOTE: Data applies only to
North America
Part # 1955200 Rev.6 (07/03/12)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Master 200Master 450Master 455Master 475

Table of Contents