Icom IC-F50 Instruction Manual

Uhf transceiver and vhf transceiver
Hide thumbs Also See for IC-F50:

Advertisement

INSTRUCTION MANUAL
VHF TRANSCEIVER
iF50
UHF TRANSCEIVER
iF60
This device complies with Part 15 of
the FCC rules. Operation is subject to
the condition that this device does not
cause harmful interference.

Advertisement

Table of Contents
loading

Summary of Contents for Icom IC-F50

  • Page 1 INSTRUCTION MANUAL VHF TRANSCEIVER iF50 UHF TRANSCEIVER iF60 This device complies with Part 15 of the FCC rules. Operation is subject to the condition that this device does not cause harmful interference.
  • Page 2: Safety Training Information

    Population” in an uncontrolled environment. This radio has been tested and complies with the FCC RF exposure lim- its for “Occupational Use Only”. In addition, your Icom radio complies with the following Standards and Guidelines with regard to RF energy and...
  • Page 3 • ALWAYS keep the antenna at least 2.5 cm (1 inch) away from the body when transmitting and only use the Icom belt-clip which is listed on page vi when attaching the radio to your belt, etc., to ensure FCC RF exposure compliance requirements are not exceeded.
  • Page 4: Foreword

    FOREWORD READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL— This instruction manual contains important operating instructions for the IC-F50 and IC-F60 TRANSCEIVER UHF TRANSCEIVER EXPLICIT DEFINITIONS WORD DEFINITION Personal injury, fire hazard or electric shock RWARNING may occur.
  • Page 5: Precaution

    The use of non-Icom battery packs/chargers may impair transceiver performance and invalidate the warranty. FCC caution: Changes or modifications to this device, not expressly approved by Icom Inc., could void your authority to operate this transceiver under FCC regulations.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS SAFETY TRAINING INFORMATION …………………………………… i FOREWORD ……………………………………………………………… iii EXPLICIT DEFINITIONS ………………………………………………… iii OPERATING NOTES …………………………………………………… iii PRECAUTION …………………………………………………………… iv TABLE OF CONTENTS ………………………………………………… v SUPPLIED ACCESSORIES …………………………………………… vi 1 ACCESSORIES ……………………………………………………… 1–2 ‘ Accessory attachments ……………………………………………… 1 2 PANEL DESCRIPTION ……………………………………………...
  • Page 7: Supplied Accessories

    Attach the supplied function name stickers above the appropriate keys for easy recognition of that key’s assigned function. Versions of the IC-F50/F60 which display the “FM AP- PROVED” symbol as at left on the serial number seal, con- form to intrinsically safe ratings of the FMRC (Factory Mutual Research Corporation).
  • Page 8: Accessories

    ACCESSORIES I Accessory attachments D Flexible antenna Connect the supplied flexible antenna to the antenna connector. CAUTION! • NEVER HOLD by the antenna when carrying the transceiver. • Transmitting without an antenna may damage the transceiver. ï Battery pack To attach the battery pack: Slide the battery pack on the back of the transceiver in the direc- tion of the arrow (q), then lock it with the battery release button.
  • Page 9: Accessories

    ACCESSORIES ï Jack cover Attach the jack cover when the optional speaker-microphone is not used. To attach the jack cover: To detach the jack cover: q Insert the jack cover into the e Unscrew the screw with a [SP MIC] connector. phillips screwdriver.
  • Page 10: Panel Description

    PANEL DESCRIPTION I Front, top and side panels Speaker (See the following NOTE.) Microphone Function display (p. 6) NOTE: If the speaker netting (for dust proofing) becomes wet, dry it with a hair drier (cool mode) etc. before operating the trans- ceiver.
  • Page 11 PANEL DESCRIPTION r SPEAKER-MICROPHONE CONNECTOR [SP MIC] Connects the optional speaker-microphone. (p. 54) [SP MIC] jack cover NOTE: KEEP the [SP MIC] jack cover attached to the transceiver when the speaker- microphone is not used. (See p. 2 for details) t DEALER-PROGRAMMABLE KEYS [P0] to [P3] The desired functions can be assigned independently by your dealer.
  • Page 12: I Function Display

    PANEL DESCRIPTION I Function display q OUTPUT POWER INDICATOR Appears when Low 2 or Low 1 is selected. w AUDIBLE INDICATOR ➥ Appears when the channel is in the ‘audible’ (unmute) condi- tion. ➥ Appears when the specified 2/5-tone/BIIS code is received. e COMPANDER INDICATOR Appears when the compander function is activated.
  • Page 13 [Red], [ ] and [ ] programmable function keys. Consult your Icom dealer or system operator for details concerning your transceivers programming. If the programmable function names are bracketed in the following explanations, the specific switch used to activate the function de- pends on programming.
  • Page 14: Programmable Function Keys

    PANEL DESCRIPTION PRIORITY CHANNEL KEYS ➥ Push to select Priority A or Priority B channel. ➥ Push and hold [Prio A (Rewrite)] to rewrite the Prio A channel. MR-CH 1/2/3/4 KEYS Select an operating channel directly. MONITOR KEY ➥ Mute and release the CTCSS (DTCS) or 2-tone squelch mute. Open any squelch/deactivate any mute while pushing this key.
  • Page 15 PANEL DESCRIPTION C.TONE CHANNEL ENTER KEY Select the continuous tone channel using [CH Up]/[CH Down] keys to change the tone frequency/code setting after pushing this key for permanent operation. TALK AROUND KEY Turn the talk around function ON and OFF. •...
  • Page 16 PANEL DESCRIPTION EMERGENCY KEYS ➥ Push and hold to transmit an emergency call. ➥ When [Emergency Single (Silent)] or [Emergency Repeat (Silent)] is pushed, an emergency call is transmitted without a beep emission and LCD indication change. • If you want to cancel the emergency call, push (or push and hold) the key again before transmitting the call.
  • Page 17 PANEL DESCRIPTION VOICE SCRAMBLER FUNCTION Push to toggle the voice scrambler function ON and OFF. COMPANDER KEY Push to toggle the compander function ON and OFF. The compander function reduces noise components from the trans- mitting audio to provide clear communication. USER SET MODE KEY ➥...
  • Page 18: Panel Description

    PANEL DESCRIPTION MDC CALL KEY (MDC operation only) ➥ Push to enter the MDC menu selection mode. Then select the desired MDC menu from “SELCALL,” “MSG,” “STATUS,” “RADIOCHK” and “CALALERT” using [CH Up]/[CH Down]/ [MDC Up]/[MDC Down]. After selection, push this key again to enter the transceiver alias or message channel selection mode.
  • Page 19: Conventional Operation

    CONVENTIONAL OPERATION I Turning power ON q Rotate [VOL] to turn power ON. w If the transceiver is programmed for a start up passcode, input digit codes as directed by your dealer. • The keys in the table below can be used for password input: •...
  • Page 20: Call Procedure

    CONVENTIONAL OPERATION I Call procedure When your system employs tone signalling (excluding CTCSS and DTCS), the call procedure may be necessary prior to voice trans- mission. The tone signalling employed may be a selective calling system which allows you to call specific station(s) only and prevent unwanted stations from contacting you.
  • Page 21: Receiving And Transmitting

    CONVENTIONAL OPERATION I Receiving and transmitting NOTE: Transmitting without an antenna may damage the trans- ceiver. See p. 1 for antenna attachment. Receiving: q Rotate [VOL] to turn power ON. w Push [ ] or [ ] to select a channel. e When receiving a call, adjust the audio output level to a comfort- able listening level.
  • Page 22: D Transmitting Notes

    CONVENTIONAL OPERATION D Transmitting notes • Transmit inhibit function The transceiver has several inhibit functions which restrict trans- mission under the following conditions: - The channel is in mute condition (‘Inaudible’ condition; “ ” does not appear). - Channel is busy. - Un-matched (or matched) CTCSS is received.
  • Page 23 CONVENTIONAL OPERATION D TX code number edit (PMR or BIIS PMR operation only) If the transceiver has [TX Code CH Select] or [TX Code Enter] as- signed to it, TX code contents can be edited within the allowable digits. TO EDIT A TX CODE VIA [TX CODE CH SELECT] KEY: q Push [TX Code CH Select] to enter the TX code channel selec- tion mode.
  • Page 24: Scrambler Function

    CONVENTIONAL OPERATION D DTMF transmission If the transceiver has [DTMF Autodial] assigned to it, the automatic DTMF transmission function is available. Up to 8 DTMF channels are available. TO SELECT A TX CODE: q Push [DTMF Autodial]— a DTMF channel appears. w Push [ ] to select the desired DTMF channel.
  • Page 25: User Set Mode

    CONVENTIONAL OPERATION I User set mode User set mode is accessed at power ON and allows you to set seldom-changed settings. In this case you can “customize” trans- ceiver operation to suit your preferences and operating style. Entering the user set mode: q While pushing and holding [ ] and [ ], rotate [VOL] to enter...
  • Page 26: Biis Operation

    BIIS OPERATION I Default setting The following functions are assigned to each programmable switch as the default. Ask your dealer for details. [P0]; Call : Push to transmit a 5-tone/BIIS call when the selected channel is a 5-tone or MSK channel, respectively.
  • Page 27: Receiving A Call

    BIIS OPERATION I Receiving a call D D Individual call q When an individual call is received; • Beeps sound. • “ ” appears and the mute is released. • The programmed text message (e.g.“ ”) and the calling station ID (or text) is displayed alternately, depending on the set- ting.
  • Page 28: D Group Call

    BIIS OPERATION D D Group call q When a group call is received; • Beeps sound. • “ ” appears and the mute is released. • The programmed text message (e.g.“ ”) and the calling sta- tion ID (or text) is displayed alternately, depending on the setting. •...
  • Page 29: D Displaying The Received Call Record

    BIIS OPERATION D D Displaying the received call record — Queue indication The transceiver memorizes the calling station IDs for record. Up to 3 calls can be memorized, and the oldest call record is erased when a 4th call is received. However, once the transceiver is pow- ered OFF, the all records are cleared.
  • Page 30: Transmitting A Call

    BIIS OPERATION I Transmitting a call Total of a 3 ways for code selection are available—selecting the call code from memory, entering the call code from the keypad and call- ing back from the queue channel record. D D Using call memory q While in the standby condition, push [P1] (Digital) to enter the call code memory channel selection mode.
  • Page 31: D Calling Back From The Queue Channel

    BIIS OPERATION D D Calling back from the queue channel q While in the standby condition, push [P1] (Digital) for 1 sec. to enter queue memory channel selection mode. w Push [ ] to select the desired record. e Push [P0] (Call) or [PTT]* to call. *PTT call can be made only when PTT call capability is permitted.
  • Page 32: D Direct Code Entry

    BIIS OPERATION D D Direct code entry q While in the standby condition, push [TX Code Enter] to enter the TX code edit mode. • Editable code digit blinks. w Push [TX Code Enter] to select the desired digit to be edited. •...
  • Page 33: Receiving A Message

    BIIS OPERATION I Receiving a message D D Receiving a status message q When a status message is received; • Beeps sound. • The calling station ID (or text) and the status message is displayed alternately, depending on the setting. w Push [P3] (Moni(Audi)) to return to the standby condition.
  • Page 34 BIIS OPERATION D D Receiving an SDM q When an SDM is received; • Beeps sound. • The calling station ID (or text) and the SDM is displayed alternately, depending on the setting. w When the received SDM includes more than 8 characters, the message scrolls automatically, when the automatic scroll func- tion is activated.
  • Page 35: D Received Message Selection

    BIIS OPERATION D D Received message selection The transceiver memorizes the received messages for record. Up to 6 messages for status and SDM, or 95 character SDM’s can be memorized. The oldest message is erased when the 7th message is received. However, once the transceiver is powered OFF, all messages are cleared.
  • Page 36: Transmitting A Status

    BIIS OPERATION I Transmitting a status D D General The status message can be selected with the programmed text, and the message text is also displayed on the function display of the called station. Up to 24 status types (1 to 24) are available, and the status mes- sages 22 and 24 have designated meanings.
  • Page 37: Transmitting An Sdm

    BIIS OPERATION I Transmitting an SDM D D General The short data message, SDM, can be sent to an individual station or group stations. Also, 8 SDM memory channels are available and the messages can be edited via PC programming. D D Transmitting an SDM q While in the standby condition, push [P1] (Digital), then push ] to select the desired station/group code.
  • Page 38: Position Data Transmission

    BIIS OPERATION I Position data transmission When the optional OPC-966 and a GPS receiver INTERFACE CABLE is connected to the transceiver, the position (longitude and latitude) data can be transmitted automatically. Ask your dealer or system operator for connection details. The position data is transmitted when;...
  • Page 39: Printer Connection

    BIIS OPERATION I Printer connection When the optional OPC-966 is connected to the INTERFACE CABLE transceiver, a printer can be connected to print out the received SDM content and the ID of the station who sent the message. Ask your dealer or system operator for connection details. I PC connection When the optional OPC-966 is connected to the...
  • Page 40: Auto Emergency Transmission

    BIIS OPERATION I Auto emergency transmission When [Emergency Single (Silent)] or [Emergency Repeat (Silent)] is pushed, an emergency signal is automatically transmitted for the specified time period. The status 22 (Emergency) is sent to the selected ID station, and the position data is transmitted after the emergency signal when a GPS receiver is connected to the transceiver.
  • Page 41: Biis Indication

    BIIS OPERATION I BIIS indication The following indications are available for the BIIS operation on an MSK channel. : Individual/group call is successful. : Message (status or SDM) transmission is successful. : No answer back is received. : Appears during retry of the call (2nd call). : End the communication.
  • Page 42: Mdc 1200 Operation

    Check, Messaging and Emergency signaling. Also, the dispatcher can stun and revive transceivers on the system. An additional feature of MDC 1200 found in Icom transceivers is called aliasing. Each transceiver on the system has a unique ID number. Aliasing allows the substitution of an alphanumeric name for this ID number.
  • Page 43: Transmitting A Call

    MDC 1200 OPERATION I Transmitting a call D D Transmitting a Selective Call Selective calling allows you to make a call to a specific station or to a particular group. Other MDC 1200 transceivers on the channel will not receive a selective call that does not match their station or group ID’s.
  • Page 44 MDC 1200 OPERATION D D Transmitting a Call Alert Call Alert allows you to notify another user who may be away from the transceiver that you want to talk. q Push [MDC Call] to enter the MDC menu selection mode. •...
  • Page 45 MDC 1200 OPERATION D D Transmitting a Radio Check Call Radio check call allows you to determine whether another trans- ceiver is turned on, within range and on channel without requiring any action from the targeted station user. q Push [MDC Call] to enter the MDC menu selection mode. w Select “RADIOCHK”...
  • Page 46 MDC 1200 OPERATION D D Transmitting a Status Message Status Messaging allows you to send a pre-programmed status message to the dispatcher. There are 16 status codes that can be sent. In addition, the dispatcher can send an MDC 1200 signal that causes the transceiver to automatically transmit its current status.
  • Page 47 MDC 1200 OPERATION D D Transmitting a Message The transceiver can send a pre-programmed message to the dis- patcher. There are 16 messages that can be sent on a channel. q Push [MDC Call] to enter the MDC menu selection mode. w Select “MSG”...
  • Page 48 MDC 1200 OPERATION D D Emergency Calls The MDC 1200 Emergency feature can be accessed using the [Emergency] key (p. 9). The transceiver will repeatedly send an Emergency MDC 1200 command to the dispatcher for a pro- grammed length of time until it receives an acknowledgement sig- nal.
  • Page 49: Receiving A Call

    MDC 1200 OPERATION I Receiving a call D D Receiving a Selective Call q When an individual call is received; • Beeps sound, “ ” appears and “ ” blinks. • The calling station ID (or alias) and “SELCALL” are displayed alternately. Appears Blinks w Push and hold [PTT] and speak into the microphone.
  • Page 50: Mdc 1200 Operation

    MDC 1200 OPERATION D D Receiving an Emergency Call q When an emergency call is received; • Beeps sound. • The calling station ID (or alias) and “EMG EMG” are displayed al- ternately. w Turn power OFF, change the channel, etc. to stop the beep and display indication.
  • Page 51: Battery Charging

    BATTERY CHARGING I Battery charging Prior to using the transceiver for the first time, the battery pack must be fully charged for optimum life and operation. CAUTION: To avoid damage to the transceiver, turn it OFF while charging. • Recommended temperature range for charging: +10°C to +40°C (+50°F to +104°F) - The Li-Ion battery functions within –20°C to +60°C (–4°F to +140°F)
  • Page 52: Caution

    BATTERY CHARGING I Caution CAUTION! NEVER insert battery pack/transceiver (with the bat- tery pack attached) with wet or soiled into the charger. This may re- sult in corrosion of the charger terminals or damage to the charger. The charger is not waterproof and water can easily get into it. NEVER incinerate used battery packs.
  • Page 53: Optional Battery Chargers

    BATTERY CHARGING I Optional battery chargers ï Regular charging with the BC-152 q Attach the BC-152 to a flat surface, such as a desk, if desired. w Connect the AC adapter (BC-147A/E*) as shown below. *Depending on version. e Insert the battery pack with/without the transceiver into the charger.
  • Page 54 BATTERY CHARGING D For your convenience Eyelet USE a rubber band to secure the transceiv- er while charging, if desired.
  • Page 55 BATTERY CHARGING ï AD-100 installation q Install the AD-100 desktop charger adapter into the holder space of the BC-119N/121N. w Connect the plugs of the BC-119N/121N to the AD-100 with the connector, then install the adapter into the charger with the sup- plied screws.
  • Page 56 BATTERY CHARGING D Rapid charging with the BC-119N+AD-100 The optional BC-119N provides rapid charging of optional Li-Ion battery packs. The following are additionally required: • One AD-100 (purchase separately) • An AC adapter (may be supplied with BC-119N depending on ver- sion) or the DC power cable (OPC-515L/CP-17L).
  • Page 57 BATTERY CHARGING D Rapid charging with the BC-121N+AD-100 The optional BC-121N allows up to 6 battery packs to be charged simultaneously. The following are additionally required. • Six AD-100. • An AC adapter (BC-157) or the DC power cable (OPC-656) Transceiver Turn power OFF Battery pack...
  • Page 58: Optional Battery Case

    BATTERY CHARGING I Optional battery case When using the optional battery case, install 5 AA (R6) size alka- line batteries as illustrated at right. The BP-226 meets JIS water- proof specification grade 4. q Hook your finger under the latch, and open the cover in the direc- tion of the arrow (q).
  • Page 59: Battery Charging

    BATTERY CHARGING Latch BP-226 Fig.1 Fig.2 Ribbon Fig.3 Gasket Ribbon...
  • Page 60: Speaker-Microphone

    SPEAKER-MICROPHONE I Optional HM-138 description Alligator type clip To attach the speaker-mic. to your shirt or collar, etc. PTT switch Transmits while pushed Receives while released Microphone Speaker NEVER immerse the connector in water. If the connector becomes wet, be sure to dry it BEFORE attaching it to the transceiver. NOTE: The microphone is located at the top of the speaker-mi- crophone, as shown in the diagram above.
  • Page 61: Attachment

    SPEAKER-MICROPHONE I Attachment Attach the connector of the speaker-microphone into the [SP MIC] connector on the transceiver and tighten the screw. CAUTION: Attach the speaker-microphone s connector securely to pre- vent accidental dropping, or water intrusion in the connector. IMPORTANT: KEEP the [SP MIC] jack cover attached (trans- ceiver) when the speaker-microphone is not in use.
  • Page 62: Options

    OPTIONS • BP-226 BATTERY CASE Battery case for 5 AA (R6) alkaline cells. • BP-227/FM BATTERY PACK 7.2 V/1700 mAh Li-Ion battery pack. The same as supplied with the transceiver. BP-227/FM must be charged with the optional BC- 152 or the BC-119N/121N. BP-227FM must be used for the intrin- sically safe type.
  • Page 63: Options

    OPTIONS • BC-121N + AD-100 (6 pcs.) MULTI CHARGER CHARGER ADAPTER + BC-157 AC ADAPTER For rapid charging of up to 6 battery packs (six AD-100’s are required) simultaneously. An AC adapter should be pur- chased separately. Charging time: approx. 2 to 2.5 hours. •...
  • Page 64 A-6533H-1EX-w Printed in Japan © 2006 Icom Inc. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan Printed on recycled paper with soy ink.

This manual is also suitable for:

Ic-f60

Table of Contents