Scanning Angle
Scanning Center
Scanning Step Angle
Time to Train
4.7
Transceiver Beam Width
(-3 dB)
4.8
Allowable Ship's Speed
4.9
Stabilizer
5
I/O INTERFACE
5.1
Data format
5.2
Input
5.3
Output
6
POWER SUPPLY
6.1
Display Unit/ Control Unit/ Transceiver Unit
6.2
Hull Unit
6.3
Rectifier (option)
7
ENVIRONMENTAL CONDITION
7.1
Ambient Temperature
7.2
Relative Humidity
7.3
Water proofing
(IEC 60529)
8
COATING COLOR
8.1
Display Unit/ Control Unit
8.2
Transceiver Unit
6 to 180 , 12 step
0 to 180 , 6 step
Normal: 3 , High speed: 6
360 , 6 step
Frequency
Vertical
60 kHz:
12
88 kHz:
9.5
150 kHz:
6.5
20 knot or less (15 knot during raise/lower operation)
Within 30 , optional motion sensor or clinometers required
IEC61162-1 (NMEA0183 Ver 1.5/2.0)
DBS, DBT, DPT, GGA, GLL, HDG, HDM, HDT, MDA, MTW, RMA,
RMC, VDR, VHW, VTG
SSTLL
12-32 VDC: 4.7-1.8 A, within 58 VA
12/24-32 VDC: 4.7/2.3-1.8 A, within 58 VA
Max. 16.7/8.2-7.7 A, within 200-246 VA
110/220 VAC, 13 A, 1 phase, 50/60 Hz
-15°C to +55°C (Soundome: 0°C to +35°C)
95%
Display/ Control unit: IPX5
Transceiver unit/ Hull unit: IPX2
Panel: N3.0, Chassis: 2.5GY5/1.5
N3.0
SP - 3
Horizontal
15
11.5
6.5
E1316S01G