Step 4 : Check
When analysis is complete, "Parameter Check<" is displayed.
Press
o
and check the analysis results for the following four items.
q Make your selection using u
and press
i
• Presence and size of speaker
"SpConfi g. Check<"
• Distance of speaker from listening position
"Distance Check<"
• Speaker channel level
"Ch Level Check<"
• Crossover Frequency
"Crossover Check<"
ui
to change which speaker is displayed.
w Use
n To switch to another analysis result item
ENTER
Press
.
This returns you to analysis results items, so repeat operation q.
n To proceed to "Step 5 : Store"
During display of crossover frequency result or analysis results item, press
• "Store<" is displayed.
• To proceed to "Step 5" without checking the analysis result, use
while "Parameter Check<" is displayed.
• Values that are different from the actual distance may be set for speakers with built-in fi lters
(subwoofers, etc). This is because fi lters add electrical delay to the signal that should be
compensated.
Step 5 : Store
The auto setup measurement results are stored in the AVR-1509.
o
while "Store<" is displayed.
q Press
• "Storing" blinks on the display panel while the results are being stored.
• When storing is complete, "Completed" is displayed followed by "Disconnect Mic".
w Disconnect the setup microphone from the AVR-1509.
n To cancel storing
Use
ui
to display "Cancel<" while "Store<" is displayed and press
• All the measured auto setup data will be erased.
NOTE
Do not turn the power off while the settings are being stored.
.
o
ENTER
.
to select "Store<"
ui
o
.
s Error Messages
If the auto setup procedure could not be completed due to speaker installation, the measuring environment,
etc. an error message is displayed. Check the relevant items and be sure to take the necessary measures. After
addressing any issues, perform the auto setup procedure over again.
Error messages (examples)
• The included setup microphone is not
connected.
M i c o r S p : N o n e
• Not all speakers could be detected.
• Too much noise in the room for
accurate measurements to be made.
A m b i e n t N o i s e
• Speaker or subwoofer sound is too
low for accurate measurements to be
made.
• Displayed speaker could not be
detected.
C a u t i o n : S p N o n e
· The front L and front R speakers
were not properly detected.
The messages alternate
· Only one channel of the surround
speakers was detected.
F R
• Displayed speaker connected with
the polarities reversed.
C a u t i o n : P h a s e
The messages alternate
S L
Select "Retry" to make the measurements again.
NOTE
Be sure to turn the power off before checking speaker connections.
Cause
Measures
• Connect
the
included
microphone to the SETUP MIC jack
on the main unit.
• Check the speaker connections.
• Either turn off any device generating
noise or move it away.
• Try again when the surroundings are
quieter.
• Check the speaker installation and the
direction in which the speakers are
facing.
• Adjust the subwoofer's volume.
• Check
the
connections
displayed speaker.
• Check the polarities of the displayed
speaker.
• For
some
speakers,
message may be displayed even if
the speaker is properly connected. If
the connection is correct, use
display "Skip<" and then press