DCA-100SSVU — GENERATOR START-UP PROCEDURE (MANUAL)
Before Starting
CAUTION - LETHAL EXHAUST HAZARD
The engine's exhaust contains harmful emissions.
ALWAYS have adequate ventilation when operating .
Direct exhaust away from nearby personnel.
WARNING - STARTING THE GENERATOR
NEVER! manually start the engine with the main , GFCI
or auxiliary circuit breakers in the ON (closed) position.
1. Place the main, G.F.C.I., and aux. circuit breakers
(Figure 38) in the OFF position prior to starting the engine.
Figure 38. Main, Aux. and GFCI
Circuit Breakers (OFF)
2. Make sure the the voltage change-over board has
been configured for the desired output voltage.
3. Connect the load to the receptacles or the output
terminal lugs as shown in Figure 13. These load
connection points can be found on the output terminal
panel and the output terminal panel's hard wire hookup
panel.
4. The output terminal lugs are protected by a plastic cover.
Remove this cover to gain access to the terminals.
Tighten terminal nuts securely to prevent load wires from
slipping out.
5. Close all engine enclosure doors (Figure 39).
Figure 39. Engine Enclosure Doors
PAGE 36 — DCA-100SSVU— OPERATION AND PARTS MANUAL — REV. #0 (11/05/07)
Manual Start-up Procedure
1. Place the engine speed switch (Figure 41) in the " LOW "
(down) position.
Figure 41. Engine Speed Switch (Low)
2. Once the engine glow plugs have been warmed, place
the MPEC Control Switch in the MANUAL position to
start the engine (Figure 42).
Figure 42. MPEC Control Switch
(Manual Position)
3. Once the engine starts, let it engine run for 1-2 minutes.
Listen for any abnormal noises. If any abnormalities
exists shutdown the engine and correct the problem.
If the engine is running smoothly, place the engine
speed switch (Figure 43) in the " HIGH " (up) position.
Figure 43. Engine Speed Switch (High)
4. Verify that the Engine Running
status LED on the MPEC unit
(Figure 44) is ON (lit) after the
engine has been started.
Figure 44. Engine Running LED (ON)