OperatiOn and parts Manual
®
MOdel dca45ssKu
MOdel dca45ssKu3
60hz WhisperWatt™ generatOr
(KuBOta V3800-di-t diesel engine)
parts list nO. M1870301504
Revision #0 (12/15/11)
To find the latest revision of this
publication, visit our website at:
www.mqpower.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.

Advertisement

Table of Contents
loading

Summary of Contents for MULTIQUIP WhisperWatt DCA45SSKU3

  • Page 1 OperatiOn and parts Manual ® MOdel dca45ssKu MOdel dca45ssKu3 60hz WhisperWatt™ generatOr (KuBOta V3800-di-t diesel engine) parts list nO. M1870301504 Revision #0 (12/15/11) To find the latest revision of this publication, visit our website at: www.mqpower.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
  • Page 2: Proposition 65 Warning

    prOpOsitiOn 65 Warning Diesel engine exhaust and some of page 2 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 3: Reporting Safety Defects

    If you believe that your vehicle has a defect that could cause a crash or could cause injury or death, you should immediately inform the National Highway Traffic Safety Administration (NHTSA) in addition to notifying Multiquip at 1-800-421-1244. If NHTSA receives similar complaints, it may open an investigation, and if it finds that a safety defect exists in a group of vehicles, it may order a recall and remedy campaign.
  • Page 4: Table Of Contents

    taBle Of cOntents dca45ssKu/ssKu3 60 hz component drawings generator Generator Assembly ......... 50-51 Control Box Assembly ........52-55 Proposition 65 Warning ........... 2 Engine and Radiator Assembly ......56-59 Reporting Safety Defects ......... 3 Output Terminal Assembly ........ 60-61 Table Of Contents ............ 4 Battery Assembly..........
  • Page 5: Parts Ordering Procedures

    , 2006 Order via Internet (Dealers Only) Best Deal! If you have an MQ Account, to obtain a Username Order parts on-line using Multiquip’s SmartEquip website! and Password, E-mail us at: parts@multiquip. com. ■ View Parts Diagrams ■ Order Parts To obtain an MQ Account, contact your District Sales Manager for more information.
  • Page 6: Safety Information

    safety infOrMatiOn Do not operate or service the equipment before reading the Potential hazards associated with the operation of this entire manual. Safety precautions should be followed at all equipment will be referenced with hazard symbols which times when operating this equipment. Failure to read and may appear throughout this manual in conjunction with understand the safety messages and operating instructions safety messages.
  • Page 7: General Safety

    safety infOrMatiOn general saFeTY „ never use accessories or attachments that are not recommended by MQ Power for this equipment. Damage CauTion to the equipment and/or injury to user may result. „ never operate this equipment without proper protective „ alWaYs know the location of the nearest clothing, shatterproof glasses, respiratory protection, fi re extinguisher.
  • Page 8: Engine Safety

    safety infOrMatiOn engine saFeTY NOTICE Danger „ never run engine without an air fi lter or with a dirty air fi lter. Severe engine damage may occur. Service air fi lter „ The engine fuel exhaust gases contain poisonous carbon frequently to prevent engine malfunction.
  • Page 9: Towing Safety

    safety infOrMatiOn Fuel saFeTY „ Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross Danger vehicle weight rating.” „ Do noT start the engine near spilled fuel or combustible „...
  • Page 10: Electrical Safety

    safety infOrMatiOn eleCTriCal saFeTY „ Make sure power cables are securely connected to the generator’s output receptacles. Incorrect connections Danger may cause electrical shock and damage to the generator. „ Do noT touch output terminals during operation. Contact with output terminals NOTICE during operation can cause electrocution, „...
  • Page 11 safety infOrMatiOn BaTTerY saFeTY environmenTal saFeTY Danger NOTICE „ Do noT drop the battery. There is a possibility that the „ Dispose of hazardous waste properly. battery will explode. Examples of potentially hazardous waste are used motor oil, fuel and fuel fi lters. „...
  • Page 12: Specifications

    specificatiOns Table 1. generator specifications model DCA-45SSKU/KU3 Revolving field, self ventilated, Type open protected type synchronous generator armature Connection star with neutral zigzag phase Single standby output 39.6 KW (49.5 kVA) 28.6 KW prime output 36 KW (45 kVA) 26 KW 3Ø...
  • Page 13: Dimensions

    diMensiOns TOP VIEW SIDE VIEW FRONT VIEW Figure 1. Dimensions Table 3. Dimensions reference Dimension in. (mm) reference letter Dimension in. (mm) letter 25.19 in. (640 mm.) 76.37 in. (1,940 mm.) M91020000 25.19 in. (640 mm.) 49.21 in. (1,250 mm.) 24.60 in.
  • Page 14: Installation

    installatiOn Figure 2. Typical Generator Grounding Application page 14 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 15: Installation

    installatiOn ouTDoor insTallaTion generaTor grounDing Install the generator in a area that is free of debris, To guard against electrical shock and possible damage to bystanders, and overhead obstructions. Make sure the the equipment, it is important to provide a good earTh generator is on secure level ground so that it cannot slide ground.
  • Page 16: General Information

    general infOrMatiOn generaTor open DelTa exCiTaTion sYsTem This generator is equipped with the state of the art “open- This MQ Power generator (Figure 3) is a high quality Delta” excitation system. The open delta system consist portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible of an electrically independent winding wound among pumps and other industrial and construction machinery.
  • Page 17: Major Components

    MajOr cOMpOnents 3 PHASE 240/139 3 PHASE 1 PHASE 480/277 240/120 PRESS TO LOCK Figure 3. Major Components Table 4. generator major Components iTem no. DesCripTion Output Terminal Panel Assembly Terminal Panel Assembly Voltage Selector Switch Assembly Coolant Drain Plug INCREASE DECREASE Fuel Drain Plug...
  • Page 18: Generator Control Panel

    engine cOntrOl panel INCREASE DECREASE STOP START Figure 4. Engine Control Panel The definitions below describe the controls and functions d. pre-heat lamp — The pre-heat lamp will be ON of the Engine Control Panel (Figure 4). during the pre-heating cycle (cold weather conditions).
  • Page 19: Engine Operating Panel

    generatOr cOntrOl panel DECREASE INCREASE STOP START Figure 5. Generator Control Panel The definitions below describe the controls and functions 6. main Circuit Breaker—This three-pole, 125A main of the Generator Control Panel (Figure 5). breaker is provided to protect the the U,V, and W Output Terminal Lugs from overload.
  • Page 20: Output Terminal Panel Familiarization

    Output terMinal panel faMiliarizatiOn ouTpuT Terminal panel ouTpuT Terminal FamiliarizaTion The Output Terminal Panel (Figure 6) shown below is The “Output Terminal Panel ” (Figure 6) is provided with located on the right-hand side (left from control panel) of the following: the generator.
  • Page 21 Output terMinal panel faMiliarizatiOn 120 vaC gFCi receptacles Each auxiliary receptacle is protected by a 50 amp circuit breaker. These breakers are located directly above the There are two 120 VAC, 20 amp GFCI (Duplex Nema GFCI receptacles. Remember the load output (current) 5-20R) receptacles provided on the output terminal panel.
  • Page 22 Output terMinal panel faMiliarizatiOn Connecting loads over Current relay Loads can be connected to the generator by the output An over current relay (Figure 12) is connected to the main Terminal lugs or the convenience receptacles (Figure 11). circuit breaker. In the event of an overload, both the circuit Make sure to read the operation manual before attempting breaker and the over current relay may trip.
  • Page 23: Load Application

    lOad applicatiOn single phase loaD Three phase loaD Always be sure to check the nameplate on the generator When calculating the power requirements for 3-phase and equipment to insure the wattage, amperage, frequency, power use the following equation: and voltage requirements are satisfactorily supplied by the generator for operating the equipment.
  • Page 24: Generator Outputs

    generatOr Outputs generaTor ouTpuT volTages generator amperage Table 8 shows the maximum amps the generator can A wide range of voltages are available to supply voltage for many different applications. Voltages are selected by using provide. Do noT exceed the maximum amps as listed.. the voltage selector switch (Figure 13).
  • Page 25: Generator Outputs/Gauge Reading

    generatOr Outputs/gauge reading hoW To reaD The aC ammeTer anD aC aC ammeter gauge reading volTage gauges Place the AC Ammeter Change-Over Switch (Figure 17) in the U position and observe the current reading (load The AC ammeter and AC voltmeter gauges are controlled drain) on the U terminal as indicated on the AC Ammeter by the AC ammeter and AC voltmeter change-over Gauge (Figure 18).
  • Page 26: Output Terminal Panel Connections

    Output terMinal panel cOnnectiOns uvWo Terminal ouTpuT volTages 3. Turn the voltage regulator knob (Figure 21) clockwise to increase voltage output, turn counterclockwise to Various output voltages can be obtained using the UVWO decrease voltage output. Use voltage regulator output terminal lugs. The voltages at the terminals are adjustment knob whenever fine tuning of the output dependent on the position of the voltage selector switch voltage is required.
  • Page 27: Output Terminal Panel Connections

    Output terMinal panel cOnnectiOns 3Ø-480/277v uvWo Terminal output voltages 1Ø-240/120v uvWo Terminal output voltages 1. Place the voltage selector switch in the 3Ø 480/277 1. Place the voltage selector switch in the 1Ø 240/120 position as shown in Figure 24. position as shown in Figure 26.
  • Page 28: Inspection/Setup

    inspectiOn/setup CirCuiT Breakers Fuel CheCk To protect the generator from an overload, a 3-pole, 125 Danger amp, main circuit breaker is provided to protect the u,v, and Fuel spillage on a hot engine can cause W output terminals from overload. In addition two single- a fire or explosion.
  • Page 29 inspectiOn/setup refueling procedure: 2. Remove fuel cap and fill tank as shown in Figure 31. Warning Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes. 1. level Tanks — Make sure fuel cells are level with the ground.
  • Page 30: Air Cleaner

    inspectiOn/setup CoolanT (anTiFreeze/summer CoolanT/ Cleaning The raDiaTor WaTer) The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the kuBoTa recommends antifreeze/summer coolant for use in radiator fins with compressed air. Cleaning inside the their engines, which can be purchased in concentrate (and machine is dangerous, so clean only with the engine turned mixed with 50% demineralized water) or pre-diluted.
  • Page 31 inspectiOn/setup BaTTerY When connecting battery do the following: 1. never connect the battery cables to the battery This unit is of negative ground Do noT connect in reverse. terminals when the mpeC Control switch is in either Always maintain battery fluid level between the specified the manual position.
  • Page 32: Generator Start-Up Procedure

    generatOr start-up prOcedure BeFore sTarTing sTarTing 1. Place the voltage selector switch in the desired CauTion voltage position (Figure 38).. The engine’s exhaust contains harmful emissions. alWaYs have adequate ventilation when operating. Direct exhaust away from nearby personnel. Warning never manually start the engine with the main, gFCi or auxiliary circuit breakers in the on (closed) position.
  • Page 33: Generator Start-Up Procedure

    generatOr start-up prOcedure 2. Depending on the temperature of the coolant (cold 6. The generator’s frequency meter (Figure 44) should be displaying the 60 cycle output frequency in herTz. weather conditions), the pre-heat lamp (Figure 41) will light (on) and remain on until the pre-heating cycle has been completed.
  • Page 34: Generator Shut-Down Procedures

    generatOr shut-dOWn prOcedures 10. Place the main, gFCi, and aux. circuit breakers in the 2. Place the engine speed control switch (Figure 51) in on position (Figure 48). the Start/Idle position (down). START/IDLE Figure 51. Engine Speed Control Switch Start Idle Position Figure 48.
  • Page 35: Maintenance

    Maintenance 10 hrs 1000 Table 14. inspection/maintenance 250 hrs 500 hrs DailY Check Engine Fluid Levels Check Air Cleaner Check Battery Acid Level Check Fan Belt Condition Check for Leaks Check for Loosening of Parts Replace Engine Oil and Filter * engine Clean Air Filter Check Fuel Filter/Water Separator Bowl...
  • Page 36 Maintenance Fuel Tank inspeCTion If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result. This can lead to In addition to cleaning the fuel tank, the following a loss of power, excessive carbon buildup in the combustion components should be inspected for wear: chamber and high fuel consumption.
  • Page 37: Check Oil Level

    Maintenance air removal Warning If air enters the fuel injection system of a diesel engine, Allow engine to cool when flushing out starting becomes impossible. After running out of fuel, radiator. Flushing the radiator while hot or after disassembling the fuel system, bleed the system could cause serious burns from water or according to the following procedure.
  • Page 38 Maintenance If the generator will be used daily, the battery should JaCkeT WaTer heaTer anD inTernal BaTTerY normally not require charging. If the generator will be idle (opTional) (not used) for long periods of time, apply power to the battery charger receptacle via commercial power using a This generator can be equipped as an option with a jacket power cord of adequate size.
  • Page 39: Trailer Maintenance

    trailer Maintenance Trailer mainTenanCe 8. Tire size — Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters This section is intended to provide the user with generic (175,185,205, etc.). The tire diameter must match the trailer service and maintenance information.
  • Page 40: Brake Adjustment

    trailer Maintenance Brakes hydraulic surge Brakes Trailer brakes should be inspected the first 200 miles of Hydraulic surge brakes (Figure 58) should not require any operation. This will allow the brake shoes and drums to seat special attention with the exception of routine maintenance properly.
  • Page 41 trailer Maintenance Tires/Wheels/lug nuTs suspension The leaf suspension springs and associated components Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the (Figure 59) should be visually inspected every 6,000 miles trailer wheels it is important the wheels, tires, and axle are for signs of excessive wear, elongation of bolt holes, and properly matched.
  • Page 42 trailer Maintenance lug nut Torque requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1.
  • Page 43: Trailer Wiring Diagram

    trailer Wiring diagraM Figure 61. Trailer/Towing Vehicle Wiring Diagram DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11) — page 43...
  • Page 44: Generator Wiring Diagram

    generatOr Wiring diagraM Figure 62. Generator Wiring Diagram page 44 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 45: Engine Wiring Diagram

    engine Wiring diagraM Figure 63. Engine Wiring Diagram DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11) — page 45...
  • Page 46: Troubleshooting (Generator)

    trOuBleshOOting (generatOr) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 19 shown below for diagnosis of the Generator. If the problem cannot be remedied, consult our company’s business office or service plant. Table 19.
  • Page 47 nOtes DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11) — page 47...
  • Page 48: Explanation Of Code In Remarks Column

    A blank entry generally indicates that the item is not sold assembly/kit that can be purchased, or is not available separately or is not sold by Multiquip. Other entries will for sale through Multiquip. be clarified in the “Remarks” Column.
  • Page 49: Suggested Spare Parts

    suggested spare parts DCa45ssku/ku3 WhisperWaTT generaTor WiTh kuBoTa v3800-Di-T-e3CB Diesel engine 1 to 3 units QTY. DesCripTion 5....1C02032433 ..CARTRIDGE , OIL FILTER 5....1663143562 ..FILTER, FUEL, MAIN 5....RB10151281 ..FILTER, FUEL, ELEMENT, PRE 2....1J41905810 ..KIT, ELEMENT, SEPARATOR 3....0602046366 ..ELEMENT, AIR 1....1G54197011 ..BELT, FAN 1....B3311501503 ..RADIATOR HOSE, UPPER 1....B3311501603 ..RADIATOR HOSE, LOWER 1....T106365660 ..SENSOR, WATER TEMP, (ENGINE SIDE)
  • Page 50: Generator Assembly

    generatOr assy. page 50 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 51 generatOr assy. parT no. parT name QTY. remarks B3110001302 ROTOR ASSY...........1 ..... INCLUDES ITEMS W/# 1-1# FIELD ASSY. 1-2# 0601820083 RECTIFIER 1-3# 06018 22664 1-4# B3120100804 HOLDER, ZNR 1-5# B3120100604 INSULATOR WASHER 1-6# B3120100704 INSULATOR WASHER 1-7# B3111100603 1-8# B2163100004 COUPLING DISK.
  • Page 52: Control Box Assy

    cOntrOl BOx assy. page 52 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 53: Control Box Assembly

    cOntrOl BOx assy. parT no. parT name QTY. remarks M1213002012 CONTROL BOX 1- 1 Y0330000555 EDGING 1- 2 Y0330000255 EDGING 1- 3 Y0330000190 EDGING 0016906016 HEX. HEAD BOLT 0601807521 CIRCUIT BREAKER, 3P 125A INSULATING PLATE 0601823863 RELAY UNIT 0027104016 MACHINE SCREW 0601820602 AUTOMATIC VOLTAGE REGULATOR 0027105016...
  • Page 54 cOntrOl BOx assy. page 54 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 55 cOntrOl BOx assy. parT no. parT name QTY. remarks 0027105010 MACHINE SCREW M9220100004 SET SCREW Y0080200007 SNAP RING M1224100104 STOPPER 0027105010 MACHINE SCREW 0601806859 AC VOLTMETER, 0-600V 0601808986 AC AMMETER, 0~75/150A:5A 0601807641 FREQUENCY METER, 6 45~65HZ 240V 1 0601801040 CHANGE— OVER SWITCH, 0601840073 VOITAGE REGUIATOR 2W 1K OHM 0601840121...
  • Page 56: Engine And Radiator Assembly

    engine and radiatOr assy. page 56 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 57 engine and radiatOr assy. parT no. parT name QTY. remarks M1923200154 ENGINE, KUBOTA V3800-DI-T 1G54197011 FAN BELT 1663143562 ELEMENT, FUEL FILTER 1C02032433 CARTRIDGE, OIL FILTER 1J41905811 ELEMENT, BROWBY GAS SEPARATOR 1 0605000451 RUBBER SUSPENSION 020310080 HEX. HEAD NUT 0040010000 WASHER, LOCK 031110160 WASHER, FLAT B3924200324...
  • Page 58 engine and radiatOr assy. (cOntinued) page 58 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 59 engine and radiatOr assy. (cOntinued) parT no. parT name QTY. remarks 011008020 HEX. HEAD BOLT Y0199101000 HOSE 0193601300 HOSE 0605515170 HOSE BAND M1310200904 BRACKET, RADIATOR M1310201004 BRACKET, RADIATOR M1310201104 BRACKET, RADIATOR 011008020 HEX. HEAD BOLT M9312200104 MOUNT RUBBER 1502025103C DRAIN JOINT ..........1 ....REPLACES P/N M9200000003 011008020 HEX.
  • Page 60: Output Terminal Assembly

    Output terMinal assy. ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT: 1-ORANGE 5-BLACK 2-WHITE 6-CATERPILLAR YELLOW 3-SPECTRUM GREY 7-CATO GOLD 4-SUNBELT GREEN 8-RED THE SERIAL NUMBER MAY BE REQUIRED. page 60 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 61 Output terMinal assy. parT no. parT name QTY. remarks M1230700103 TERMINAL PANEL M9220100204 OUTPUT TERMINAL BOLT M9220100104 TIE SCREW 0039310000 HEX. NUT 0040010000 WASHER, LOCK 0041410000 WASHER, FLAT 0016908025 HEX. HEAD BOLT M1236102013 TERMINAL COVER 011106015 HEX. HEAD BOLT M1236102114 OUTPUT WINDOW Y0605012028 HINGE...
  • Page 62: Battery Assembly

    Battery assy. page 62 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 63 Battery assy. parT no. parT name QTY. remarks 0602220199 BATTERY, 727MF M9310500014 BATTERY SHEET M9103000304 BATTERY BAND 0602220920 BATTERY BOLT SET M1346400104 BATTERY CABLE M0348200104 BATTERY CABLE CABLE, GROUND ........1 ....MAKE LOCALLY Y0013512025 HEX. HEAD BOLT 0040012000 WASHER, LOCK 031112230 WASHER, FLAT 0040512000 TOOTHED WASHER...
  • Page 64: Muffler Assembly

    Muffler assy. page 64 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 65 Muffler assy. parT no. parT name QTY. remarks B3331102203 MUFFLER 011008020 HEX. HEAD BOLT B3334001403 EXHAUST PIPE 1925812231 GASKET 0030410000 HEX. NUT 0602325097 SEAL CLAMP M1333300504 BRACKET, EXHAUST PIPE 011008020 HEX. HEAD BOLT Y0602326066 U-BOLT DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11) — page 65...
  • Page 66: Fuel Tank Assy

    fuel tanK assy. page 66 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 67: Fuel Tank Assembly

    fuel tanK assy. parT no. parT name QTY. remarks M1363002602 FUEL TANK 0605505070 FUEL TANK CAP 1- 2 0605501072 FUEL SENDER UNIT 1-2A 0605516090 GASKET M1363200104 TANK BAND M9310500104 SUPPORTER SHEET 0016908020 HEX. HEAD BOLT 0207308000 HEX. NUT 0222100600 RUBBER SHEET 0222100085 RUBBER SHEET 1502025103C...
  • Page 68: Enclosure Assembly

    enclOsure assy. page 68 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 69 enclOsure assy. parT no. parT name QTY. remarks M1413004202 BASE M1413400004 UNDER COVER 011008020 HEX. HEAD BOLT M1423003102 FRONT FRAME M1493110203 ACOUSTIC SHEET 011008020 HEX. HEAD BOLT M1423200604 COVER, FRONT FRAME M1493100804 ACOUSTIC SHEET 0019208020 HEX. HEAD BOLT M1423203303 INNER COVER, FRONT FRAME 011008020 HEX.
  • Page 70 enclOsure assy. (cOntinued) page 70 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 71 enclOsure assy. (cOntinued) parT no. parT name QTY. remarks 0019108055 HEX. HEAD BOLT 0042308000 WASHER, LOCK, STAINLESS 031108160 WASHER, FLAT 011008020 HEX. HEAD BOLT 0019208020 HEX. HEAD BOLT M1453006213 SIDE DOOR M1493414814 ACOUSTIC SHEET M1453006313 SIDE DOOR M1493414914 ACOUSTIC SHEET M1453006403 SIDE DOOR M1493415004...
  • Page 72: Rubber Seals Assembly

    ruBBer seals assy. page 72 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 73 ruBBer seals assy. parT no. parT name QTY. remarks Y0228901240 SEAL RUBBER Y0228900625 SEAL RUBBER Y0228900595 SEAL RUBBER 0229400970 SEAL RUBBER 0229400485 SEAL RUBBER Y0229400910 SEAL RUBBER Y0229400425 SEAL RUBBER 0228800515 SEAL RUBBER Y0228800820 SEAL RUBBER 0228800510 SEAL RUBBER 0228800470 SEAL RUBBER 0228100420 SEAL RUBBER...
  • Page 74: Nameplate And Decals Assembly

    naMeplate and decals assy. page 74 — DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11)
  • Page 75 naMeplate and decals assy. parT no. parT name QTY. remarks M9522000504 DECAL; CIRCUIT BREAKER ......1 ....M92200050 M9520000104 DECAL; AMMETER CHANGE-OVER SW. ..1 ....M92000010 M9522000604 DECAL; VOLTAGE REGULATOR ....1 ....M92200060 M9500400204 DECAL; STARTER SWITCH .......1 ....M90040020 M9501400004 DECAL; SPEED CONTROL ......1 ....M90140000 M9521000204 DECAL;...
  • Page 76: Terms And Conditions Of Sale - Parts

    Multiquip be $5.00. meeting this requirement. liable for loss of profit or good will or for any Special order items.
  • Page 77 nOtes DCa45ssk/ku3 60 hz generaTor • operaTion anD parTs manual — rev. #0 (12/15/11) — page 77...
  • Page 78 © COPYRIGHT 2011, MULTIQUIP INC. Multiquip Inc, the MQ logo and the MQ Power logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission.