Generator Shut-Down Procedures - MULTIQUIP DCA5USI Operation And Parts Manual

60hz whisperwatt generator (isuzu aa-4le2 diesel engine)
Table of Contents

Advertisement

Warning
never stop the engine suddenly except in an
emergency.
normal shUTDoWn proCeDUre
To shutdown the generator, use the following procedure:
1. Place both the main, gFCi and loaD circuit breakers
as shown in Figure 50 to the oFF position..
Figure 50. Main, GFCI and Load
Circuit Breakers Off
2. Let the engine cool by running it at low speed for 3-5
minutes with no load applied.
3. Place the ignition switch (Figure 51) in the "sTop"
position, remove the key and store in a safe place.
Figure 51. Ingition (Switch Normal)
4. Verify that all status LEDs on the MPEC display are
oFF (not lit).
5. Remove all loads from the generator.
6. Inspect entire generator for any damage or loosening of
components that may have occurred during operation.
page 34 — DCa25Usi 60 hz generaTor • operaTion anD parTs manUal — rev. #3 (07/19/11)

generatOr shut-dOWn prOcedures

emergenCY shUTDoWn proCeDUre
1. Place the main, g.F.C.i., and aux. circuit breakers (Figure
52) in the oFF position.
2. Turn the ignition key (Figure 52) to the sTop position.
Figure 52. Ingition Switch (Emergency)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power whisperwatt dca25usi

Table of Contents