Section 4

Operation

Operator Control Panel

Each operator panel is slightly different, depending on features of the generator you purchased.
The Operator Control Panel of Figure 4-1 is shown because it has most of the available features.
This will be used to explain how the controls operate.
AC Circuit Breakers
WARNING: Never connect this generator to any buildings electrical system unless a licensed electrician
has installed an approved transfer switch. The National Electrical Code (NEC) requires that
connection of a generator to any elastical circuit normally powered by means of an electric
utility must be connected by means of approved transfer switch equipment so as to isolate
the electrical circuit from the utility distribution system when the generator is operating.
Failure to isolate the electrical circuits by such means may result in injury or death to utility
power workers due to backfeed of electrical energy onto the utility lines.
Receptacles – Receptacles are provided to allow easy connection of electrical loads. Never connect this
generator to any buildings electrical system unless a licensed electrician has installed an
approved transfer switch. Multiple receptacles may be used at the same time provided the total
electrical load does not exceed the generators rated output.
120Volts –
30 Amps 120 Volts –
30 Amps 120/240 Volts – Twist lock NEMA L14–30R receptacle rated 250Volts at 30 Amperes.
Note: The nominal voltage produced by the generator at each receptacle is 120VAC or 240VAC.
MN2412
Figure 4-1 Operator Control Panels
Press to Reset
Provide overcurrent protection for the generator output. When tripped, the plunger (in
center of breaker) will extend out about 3/8 inch. Remove the loads, push the plunger
into the breaker to reset the breaker the restore the loads.
PC30H has no GFCI protection, 3 outlets rated 125VAC at 15 Amperes.
All others have NEMA 5–20R GFCI Duplex receptacle provides ground fault
protection. Rated 125VAC at 20 Amperes.
Twist lock NEMA L5–30R receptacle, rated 125 Volts at 30 Amperes.
Press to Reset
Operation 4-1