OPERATOR'S MANUAL
FOR YOUR
PREMIER 'K' SERIES
GENERATOR
BALDOR GENERATORS
3815 OREGON STREET OSHKOSH WI 54902
Phone: (920) 236-4200 Fax: (920) 236-4219
Toll Free: 800-872-7697

Advertisement

loading

Summary of Contents for Baldor Premier 'K'

  • Page 1 OPERATOR'S MANUAL FOR YOUR PREMIER ‘K’ SERIES GENERATOR BALDOR GENERATORS 3815 OREGON STREET OSHKOSH WI 54902 Phone: (920) 236-4200 Fax: (920) 236-4219 Toll Free: 800-872-7697...
  • Page 2 DO NOT OPERATE THIS GENERATOR SET UNTIL YOU CAREFULLY READ THIS MANUAL AND UNDERSTAND THE SAFETY WARNINGS AND INSTRUCTIONS CONTAINED IN IT. While safety is built into every Baldor Pow'R Gard generator set, careless or improper operation could possibly result in mechanical failure, property damage, severe injury or even death.
  • Page 3 ♦ Place protective covers and guards over the rotating parts, if rotating parts such as the drive shaft, pulley, belt, etc. are left exposed, they are potentially hazardous. ♦ When cleaning, repairing or inspecting, make sure all moving parts have stopped. ♦...
  • Page 4 ♦ Know how to stop the engine quickly and understand the operation of all controls. ♦ Never permit anyone to operate the generator set without proper instructions. ♦ Never allow children to operate the generator set. ♦ Children and pets must be kept away from the area of operation due to the possibility of burns from hot engine components or injury from any equipment the generator set is powering.
  • Page 5 ♦ Always treat the electrical circuits as if they were energized. ♦ Disconnect all leads plugged into the unit Prior to working on it. ♦ Have the electrical circuits serviced only by qualified technicians. ♦ Inspect wiring frequently and replace frayed, broken or poor leads. ♦...
  • Page 6 Operation inside an enclosed compartment or building is a potential fire hazard and should not be done unless approval is obtained from Baldor Generators. Engine/Generator overheating can cause severe damage due to restricted, obstructed or improper air-flow that is necessary for the proper cooling of the unit.
  • Page 7: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Basic Location Information………………………………………………………………………………………….1 Basic Connection Information…………………………………………………………………………………….2 Basic Engine Information……………………………………………………………………………………………….3 Generator End Maintenance…………………………………………………………………………………………….4 Basic Engine Maintenance……………………………………………………………………………………………….5 Storage Information…………………………………………………………………………………………………………….6 Electric Motor Loads………………………………………………………………………………………………………….7 Parts and Service Information………………………………………………………………………………….8 Operation……………………………………………………………………………………………………………………………………….9 Simple Troubleshooting…………………………………………………………………………………………………….11 Control Panel for K3000………………………………………………………………………………………………….14 Control Panel for K5000/K5000E……………………………………………………………………………….15 Control Panel for K6500/K6500E……………………………………………………………………………….16 Wiring Diagram: K3000…………………………………………………………………………………………………….17...
  • Page 8 LOCATION For best service from your portable generator set there are several factors which should be taken into consideration when choosing the best location in wh ch to operate it: MOISTURE: All electrical equipment should be protected from excessive moisture. Failure to do so will result in deterioration of the insulation and may result in short circuits and a possible electrocution hazard.
  • Page 9 CONNECTIONS WIRING: Use sufficiently large insulated wire to connect the generator set to the load. The gauge of the wire will depend largely on the distance, the permissible voltage drop, and the size and type of load. you are not sure of the gauge wire needed for your application, consult a competent electrician. FRAYED, CUT, BROKEN, LOOSELY CONNECTED, OR IMPROPERLY SIZED POWER CORDS OR WIRES CAN CAUSE EQUIPMENT DAMAGE, FIRE, SEVERE INJURY OR DEATH.
  • Page 10 ENGINE INFORMATION This operator's manual only covers basic day- to- day engine operating instructions. However, the engine manufacturer's manual is included with your generator set and should be referred to for any additional information you may need. Become familiar with and follow all the engine manufacturer's operation, safety and maintenance guidelines.
  • Page 11: Generator End Maintenance

    MAINTENANCE MAINTENANCE SHOULD ONLY BE PERFORMED ON THE GENERATOR SET AFTER THE ENGINE HAS STOPPED AND THE GENERATOR SET HAS COOLED DOWN. THE BATTERY AND SPARK PLUG SHOULD ALSO BE DISCONNECTED PRIOR TO PERFORMING MAINTENANCE. GENERATOR END MAINTENANCE Generator end maintenance consists of cleaning the generator set, inspecting the wiring and fuel system, and making any necessary adjustments.
  • Page 12: Operation

    ADJUSTMENTS: √ The engine should be checked for proper speed setting(s). √ prior to adjusting the engine speed, turn the Auto Idler OFF (If your generator set is equipped with this feature). Adjust the engine speed to 3720 RPM's (62 Hertz) with no load applied to the generator set.
  • Page 13 STORAGE If you will not be using the generator set for a significant amount of time (3 months or longer) you should store the generator to prevent any problems that could arise from sitting idle. Please fully read the following guidelines prior to storing the unit. Remove all fuel from the engine's fuel tank.
  • Page 14 USE OF ELECTRIC MOTORS Electric motors require much more current (amperes) to start them than to run them. Some motors, particularly split-phase motors are very difficult to start and requires 5 to 7 times as much current to start them as it does to run them. Capacitor Motors are a little easier to start and usually require 2 to 4 times as much current to start them as to run them.
  • Page 15: Ordering Parts

    NOTE: Engine parts can usually be obtained from a local representative of your engine manufacturer via the information in the engine manufacturer's Owner's Manual. Baldor Generators or your local Baldor office can obtain engine parts if necessary. However we do not stock engine parts nor are we a dealer in engine parts.
  • Page 16 OPERATION PRIOR TO STARTING THE UNIT: 1. Locate and set up the generator set in an open, dry, well ventilated and reasonably level location. OPERATING THIS UNIT IN AN AREA NOT SUITABLE FOR IT'S PROPER USE MAY CAUSE DAMAGE TO THE UNIT, SEVERE INJURY, OR DEATH. SEE "LOCATION INFORMATION"...
  • Page 17 3. Pull lightly on the recoil grip until you feel significant resistance, then pull sharply. Do not allow the recoil rope to 'snap' back into the recoil housing. Allow the recoil to gently rewind into the recoil housing. See your engine manual for instructions specific to your unit.
  • Page 18 Listed below are the more simple solutions to some of the more common problems that are reported to the Customer Service Department at Baldor Generators. These troubleshooting solutions are meant to be an aid for a person who has minimal electrical knowledge and experience. More in-depth, detailed troubleshooting information for a person more knowledgeable and experienced in electricity can be obtained by contacting the Customer Service Department at Baldor Generators by calling (920) 236-4200.
  • Page 19 Stop the unit after doing this and replace the end -cover. If you still have no output, look for other reasons or contact the Customer Service Department at Baldor Generators.
  • Page 20 AUTO IDLER SYSTEM NOT WORKING PROPERLY (Applies only to Generator Sets equipped with this feature) For the Auto Idler System to work, the generator set must be producing normal voltage output. If the generator set is not producing any power, the Auto Idler System will not work. 1.
  • Page 21: K3000

    CONTROL PANEL For K3000 A = DC POWER SWITCH - This is your On/Off switch for which to operate the generator. B = ELAPSED TIME METER. This meter displays a continuous running total of the hours accumulated on the unit. C = AC VOLTMETER.
  • Page 22: K5000/K5000E

    CONTROL PANEL For the K5000/K5000E Units A = THE AUTO IDLER FEATURE ON/OFF SWITCH. The Auto Idler feature allows the engine on the generator set to slow down to a "slow speed position" when there is no load being applied to the unit.
  • Page 23: K6500/K6500E

    CONTROL PANEL For the K6500/K6500E Generator A = THE AUTO IDLER FEATURE ON/OFF SWITCH. The Auto Idler feature allows the engine on the generator set to slow down to a "slow speed position" when there is no load being applied to the unit. When a load is applied to the unit, the Auto Idler Circuitry allows the engine to speed up and operate at the engine preset speed.
  • Page 24: Wiring Diagram

    K3000 Wiring Diagram - 17 -...
  • Page 25 K5000 Wiring Diagram - 18 -...
  • Page 26 K5000E Wiring Diagram - 19 -...
  • Page 27 K6500 Wiring Diagram - 20 -...
  • Page 28 K6500E Wiring Diagram - 21 -...
  • Page 29 Generator-End Componentry - 22 -...
  • Page 30 CONTROL BOX COMPONENTRY - 23 -...
  • Page 31 PARTS BREAKDOWN K3000, K5000, K5000E, K6500, K6500E Units: DESCRIPTION PART # 61SA0036A00 Stator Assembly 61SA0036A01 Stator Assembly 61SA0036A02 Stator Assembly 61RA0011A00 Rotor Assembly 61RA0013A00 Rotor Assembly 61RA0015A00 Rotor Assembly CT0046A00 Idler Transformer 61FN3000 DI0176A01SP Diode EH0435A00L2B Control Cover BA0187A02R2B Base / Wrap Frame BA203A02R2B Base / Wrap Frame HA1037A00...
  • Page 32 Customers who are unable to take or ship the Baldor product to a Baldor Generator repair facility, or who desire a repair to be made by other than a Baldor Generator repair facility, should contact Baldor Generators’ Customer Service Department at 920-236-4200.
  • Page 33 For all other products, a Start-up Inspection Form / Warranty Registration must be completed in its entirety and submitted to Baldor Generators within 30 days of start-up to qualify for any warranty consideration. Owner’s Responsibilities: The owner is obligated to operate and maintain the generator in accordance with the recommendations published by Baldor Generators in the Operator’s Manual for the generator.
  • Page 34 Limitations: Baldor Generators is not responsible for the repair of generators required because of normal wear, accident, misuse, abuse, improper installation, lack of maintenance, unauthorized modifications or improper storage. Normal Wear: This warranty will not cover repair where normal use has exhausted the life of a part or generator.
  • Page 35: California Proposition 65 Warning

    CALIFORNIA PROPOSITION 65 WARNING Engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects, and other reproductive harm. CALIFORNIA PROPOSITION 65 WARNING Diesel engine exhaust and some constituents are known to the state of California to cause cancer, birth defects, and other reproductive harm.
  • Page 36 Service is just a phone call away: 800-872-7697 www.baldor.com/products/generators.asp 3815 Oregon Street Oshkosh WI 54902 Phone: (920) 236-4200 Fax: (920) 236-4219...