Section 4

Operation

Operator Control Panel

The Operator Control Panel is shown in Figure 4-1.
Oil Level
Auto Power Save Switch
Lamp
Multi Monitor Display
STOP
Auto
Engine
P−Save LED
Switch
Multi Monitor Display
Overload Display
Units LED's
Units Select Switch
Oil Level Lamp
Auto Power Save Switch Press
Auto P−Save LED
Engine Switch
Key Switch
MN2403
Figure 4-1 Operator Control Panel
Units LED's
Units
Select
Switch
STOP
ON
ON
START
CHOKE
Key
Switch
A five digit display for messages or display of Hours, Volts or Hertz.
"O_LOD" is displayed on the Multi Monitor display when generator is running and an
overload condition exists. To reset, Stop the generator and Start the generator again to
resume operation.
When Units Select Switch is set to Hours, Units Hours LED is ON and
operating hours is displayed on Multi Monitor Display.
When Units Select Switch is set to V, Units V LED is ON and
Generator Output Volts is displayed on Multi Monitor Display.
When Units Select Switch is set to Hz, Units Hz LED is ON and
Generator Output Frequency is displayed on Multi Monitor Display.
Pressing
Switch changes display modes from Hours, Volts and Hz.
Lamp is on when engine oil level is less than a predetermined level. When the lamp
turns ON, the engine will stop automatically. If Oil Lamp is ON, replenish the engine oil
level and restart the engine.
to select Power Save Mode, (Auto P−Save LED is ON) and generator speed
changes for the applied load. Output voltage and frequency remain constant even at
engine idle speed.
Press
again to deselect Power Save mode and generator runs at full speed and
produces full power. Use this mode (Auto P−Save LED is OFF) for DC power.
OFF when generator runs at full speed and produces full power.
ON when generator is in Power Save Mode (Adjustable Speed).
Stop
In this position, the engine is stopped and fuel supply line is closed.
Run
Allows the engine to start and run during normal operation.
Choke
Allows cold weather starting, place the Engine Switch in the Run position
after engine is started.
Stop
In this position, the engine is stopped.
ON
Engine run position after starting.
Start
Engine start position, engages engine starter to crank the engine.
~ AC OUTPUT
DC
NEMA 5−20R
Breaker
− +
BATTERY CHARGE ONLY
DC 12V − 8.3A
(−) Battery Charger
(+) Battery Charger
Connection
Connection
NEMA L530R
+
Ground
Terminal
Operation 4-1