WARNING: CALIFORNIA PROPOSITION 65 WARNING: Engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects and other reproductive harm. WARNING: CALIFORNIA PROPOSITION 65 WARNING: Battery posts, terminals and related accessories are known to the state of California to cause cancer, birth defects and other reproductive harm.
Any person that installs or repairs this generator must have these specialized skills to ensure that this generating unit is safe to operate. Contact Baldor service department for repairs or any questions you may have about the safe installation and operation of this system.
Symbols This symbol is shown throughout the manual to indicate a connection to ground reference point. Indicates a potentially hazardous situation which, if not avoided, could result in injury or death. Indicates a potentially hazardous situation which, if not avoided, could result in injury or death. Precaution Statements Used In This Manual There are three classifications of precautionary statements used in this manual.
Page 7
Operation Warning Statements Continued WARNING: Hot exhaust gasses must never be directed toward anything that may catch fire or explode. WARNING: This generator must not be used on or near any forest covered, brush covered, or grass covered land unless the engine’s exhaust system is equipped with a spark arrestor. The spark arrestor must be maintained in effective working order by the operator.
Page 8
WARNING: Installation and repair procedures requires specialized skills with electrical generating equipment and small engine systems. Any person that installs or performs repairs must have these specialized skills to ensure that the generator set is safe to operate. Contact Baldor for installation or repairs.
Page 9
Warning Statements Continued WARNING: Incorrect installation of this generator set could result in property damage, injury or death. Connection of the generator to its fuel source must be done by a qualified professional technician or contractor. WARNING: Never stand under or close to an object that is being hoisted or lift into position. Accidents happen and if the object falls or tips over you or someone else could be crushed by the weight of the object causing severe injury or death to to yourself or others.
Caution Statements Caution: Avoid installing the generator set beside heat generating equipment, or directly below water or steam pipes or in the vicinity of corrosive substances or vapors, metal particles and dust. Heat can cause engine problems to develop and unwanted substances can cause rust or generator failure over time.
Limited Warranty Baldor Generators will replace or repair free of charge any part or parts of the generator of their manufacture that are defective in workmanship and materials for a period of time as set forth in the Warranty Period chart below. All Baldor products requiring warranty service shall be transported or shipped freight pre−paid, at the risk of the party requiring...
Section 3 Receiving & Installation Receiving & Inspection When you receive your generator, there are several things you should do immediately. Observe the condition of the shipping container and report any damage immediately to the commercial carrier that delivered your system. Verify that the part number of the system you received is the same as the part number listed on your purchase order.
Access must be provided to allow the enclosure covers to be opened or removed for service and maintenance. Maximum Ambient temperature is 122°F (50°C). Figure 3-2 Generator Mounting (Skid) TS130/175 only (4 Holes) TS25/45/80 only (3 Holes) Table 3-1 Mounting Dimensions Generator TS25 74.0 8.12...
Hot Exhaust Gasses WARNING: Exhaust fumes/gases are extremely dangerous and can cause severe illness or death. Never breath exhaust fumes produced by a running engine. Only run the engine outdoors where ventilation is plentiful. Exhaust gases contain carbon monoxide, a colorless, odorless and extremely dangerous gas that can cause unconsciousness or death.
UL listed circuit breaker with the appropriate ratings shall be provided within 25 feet of the Genset. Use only copper wires. Input Breaker Input Breaker Generator Generator Generator Catalog No. 3 Phase VAC 3 Phase Amps TS25 208/240/480 62.5/54.1/27.1 TS45 208/240/480 121.4/105.3/52.6 TS80 208/240/480 190.8/165.4/90.2 TS130 208/240/480 329.6/285.7/145.8...
Page 17
Figure 3-3. Simply open the rear panel access door and make the connections. When the panel door is closed, the connections are weather tight. Figure 3-3 Receptacle Panel (Single Phase) TS25 Use mating plug for a CS6369 250V 50A receptacle.
Page 18
Transfer Switch Considerations The following are general considerations for the safe use of a transfer switch: The transfer switch should be located inside the building near the main breaker box or the disconnect box. The transfer switch must be kept away from any location that might allow water to get on it.
Figure 3-5 Frame Ground Connection Washer Ground Wire Lug Washer Stud Earth Ground Frame Open the enclosure access panel door 2 ( Figure 3-2). Connect the ground wire to the “earth ground” terminal shown in Figure 3-5. This ground is the local reference ground to ground the generator frame only. Caution: This generator must have a battery installed for operation.
Post Installation Checks When the initial installation is complete, these checks must be performed before starting the engine. These checks are not required before each start, only after the initial installation. Generators that have been in transit or storage for long periods may be subjected to extreme temperature and moisture changes.
Page 22
Post Installation Checks Continued 16. Place the voltage output selector switch in the appropriate position (120/240 so the receptacles are powered or as required for your load). 17. Verify all loads are disconnected. 18. Verify that the Master Control Switch is still in the “Stop” position. Connect the engine starting battery to the starter.
Section 4 Operation Towing the Generator WARNING: Never allow a person to ride in or on a trailer that is being towed. All states prohibit passengers in towed vehicles. A person can fall off and be struck be another vehicle or run over by the towed trailer.
Selecting the Proper Towing Equipment Continued Electrical Trailer Wiring All trailers must have taillights, brake lights and turn signals connected to the towing vehicle’s electrical system. It is also recommended that a heavy duty turn signal flasher and emergency flasher (if separate) be installed since the trailer lights place an extra load on car flasher units. Towing Heavy Trailer Loads Trailer brakes.
Figure 4-1 Trailer Component Identification Lift Hook Battery Jack Compartment Coupler Handle Coupler Tow Vehicle Mounted Trailer Brake Pintle Hook Pintle Safety Chains Single or Safety Ball Coupler Double Axle Trailer Chains Jack Engine Compartment Caution: Large “Engine Compartment Doors” on each side of enclosure must remain closed during operation.
Towing Instructions See Figure 4-1 for component identification. Be sure the generator is off. Shut all enclosure doors and latch the locks. Back the tow vehicle to within a few inches of the trailer coupler (Pintle or Ball). Be sure the Coupler Handle is in the “UP” (open) position or the Pintle Hook is Open. Adjust the trailer jack for the height of the hitch on the tow vehicle.
Page 27
Adequate clearance must be provided for access doors to fully open. Note: The exhaust also exits radiator end. When positioning a generator system ensure position does not cause a concentration of toxic emissions. Switch the generator set to the applicable voltage setting. Connect the load(s) at the Receptacle panel connections (Figure 4-3).
Figure 4-3 Receptacle Panel (Single Phase) TS25 Use mating plug for a CS6369 250V 50A receptacle. 240V(50A) 240V(50A) 120V(20A) 120V(20A) TS45/80 For power to be applied to Use mating plug for a these receptacle, the Output CS6369 250V 50A Voltage Selector Switch must...
Automatic Start/Stop First, ensure all “Pre−start Procedures” are complete. To setup the generator for automatic operation, set the Master Control switch to the “Auto Start” position. The following happens: The engine will automatically start upon activation of the remote start contact input. The remote device initiates a start sequence upon contact closure.
Engine Controller Description When a fault circuit is programmed as a SHUTDOWN, the engine will immediately stop when the fault is activated. A specific shutdown fault can be programmed with a definite time transient delay period that must expire before the shutdown is activated. The stop sequence will cause the controllers RUN output to be immediately terminated which will cause the engine to stop.
Page 31
Adjustments Factory adjustments are correct for most applications. If you choose to change the factory settings, here is the procedure. The potentiometer and switches are shown in Figure 4-4. Overspeed (30−8500Hz) R1 Sets the RPM at which the engine will be shutdown if the engine speed exceeds this preset value.
Page 32
Engine Controller Operation Auto Mode Operation When the controller receives an automatic start signal (across pins 10 and 11), the glow plug output turns on (if switch 3=On) and the delay begins. When the glow plug delay expires, the fuel and crank outputs turn on.
Section 5 Troubleshooting and Maintenance Maintenance This manual contains only very minimal engine maintenance instructions. Refer to the engine manufacturer’s owner’s manual for specific engine maintenance instructions for your generator set. Any maintenance instructions or recommendations in the engine owner’s manual take precedence over any of the following general recommendations.
It is not an exhaustive “how to” for all types of problems. Procedures that require in depth knowledge or skills (like flashing the field) should be referred to the Baldor Generator Service Department by calling (920) 236−4200. Table 5-1 Troubleshooting Guide...
Page 35
Tighten; align coupling and alternator shaft to engine shaft. Service Service for your generator can be obtained from Baldor Generators. Please have the following information available prior to contacting the factory: The model number and serial number of the generator set.
Page 36
5-4 Troubleshooting and Maintenance MN2416...
Fuses are installed in the control box to protect the engine controller and associated control circuits. When replacing fuses, use the exact replacement fuse (manufacturer and part number). Figure A-1 Isolators & Brackets RM1088A11 (TS25−Green) RM1088A12 (TS45−Red) RM1088A25 (TS45−Green) RM1088A13 (TS80−White)
Page 53
Figure A-15 TS175 Control Panel Connection Diagram MN2416 Parts & Wiring Diagrams A-17...
Page 54
Figure A-16 TS175 Generator Lead Connection Diagram A-18 Parts & Wiring Diagrams MN2416...
Page 55
Baldor District Offices UNITED STATES FAX: 586−978−9969 TEXAS CHINA MICHIGAN Continued HOUSTON SHANGHAI JIAHUA BUSINESS CENTER ARIZONA GAND RAPIDS 4647 PINE TIMBERS ROOM NO. A−8421 PHOENIX 668 3 MILE ROAD NW SUITE # 135 808 HONG QIAO ROAD 4211 S 43RD PLACE...