Remove Oil Sentry Pressure Switch (On Models So Equipped); Remove Blower Housing; Disconnect Spark Plug Lead; Remove Rectifier-Regulator - Kohler Courage SV470 Service Manual

Vertical crankshaft
Hide thumbs Also See for Courage SV470:
Table of Contents

Advertisement

Section 8
Disassembly
Remove Oil Sentry
(On Models So Equipped)
1. Disconnect the lead from the Oil Sentry™
pressure switch.
2. Remove the pressure switch from the center
passage or adapter elbow in the closure plate. See
Figure 8-2.
Figure 8-2. Removing Oil Sentry™ Switch.

Remove Blower Housing

1. Remove the four shoulder screws securing the
blower housing to the closure plate. See Figure
8-3.
2. Lift the blower housing and separate the spark
plug lead from the corresponding slot.
Figure 8-3. Removing Blower Housing Screws.

Disconnect Spark Plug Lead

1. Carefully pull on the boot section and disconnect
the spark plug lead.
8.2
Pressure Switch
Remove Muffler
1. Remove the hex flange nuts or 5/16-18 capscrews
attaching the muffler or exhaust system to the
engine. Remove any attached brackets. See Figure
8-4.
2. Remove the muffler and gasket from the exhaust
port.
Figure 8-4. Removing Exhaust Flange Nuts (Stud
Design).
Remove Rectifier-Regulator
1. Unplug the connector from the rectifier-regulator.
2. Remove the two screws securing the rectifier-
regulator to the crankcase. Remove the rectifier-
regulator. See Figure 8-5.
Figure 8-5. Removing Rectifier-Regulator.
Remove Electric Starter
1. Disconnect the starter lead from the terminal
stud.
2. Remove the two hex flange nuts securing the
starter to the closure plate. Remove the starter.
See Figure 8-6.