Kohler Courage SV470 Service Manual page 62

Vertical crankshaft
Hide thumbs Also See for Courage SV470:
Table of Contents

Advertisement

Section 7
Electrical System and Components
Troubleshooting Guide 3 amp/70 Watt Braking Stator (Continued)
Problem
1. Make sure lights are not burned out.
2. Disconnect the braking lead (green) from
the wiring harness.
No
Lights
With engine running in the fast setting,
Or
measure voltage from braking lead to
ground using an AC voltmeter.
Battery
Charging
3. With the engine stopped, measure the
(Braking
resistance from braking lead to ground
System
using an ohmmeter.
Test)
7.10
Test
Conclusion
1. Replace burned out lights.
2. If voltage is 35 volts or more, stator
is OK. Circuitry on unit that grounds
braking lead is shorted.
If voltage is less than 35 volts, test stator
using an ohmmeter (Test 3).
3. If resistance is approximately
0.2-0.4 ohms, stator is OK.
If resistance is 0 ohms, stator is shorted.
Replace stator.
If resistance is infinity ohms, stator or
lighting lead is open. Replace stator.

Hide quick links: