Main Supply
Voltage
Current type
Connected load
Protection (slow)
Type of protection
Protective class
Maximum allowed net impedance
Water connection
Max. feed temperature
Min. feed volume
Suck height from open container (20 °C)
Max. feed pressure
Performance data
Water flow rate
Operating pressure of water (using standard
nozzle)
Max. excess operating pressure (safety valve) MPa (bar)
Max. operating temperature of hot water
Detergent suck in
Burner performance
Maximum consumption of heating oil
Max. recoil force of hand spray gun
Nozzle size
Values determined as per EN 60355-2-79
Noise emission
Sound pressure level L
Uncertainty K
pA
Sound power level L
Hand-arm vibration value
Hand spray gun
Spray lance
Uncertainty K
Fuel
Fuel
Amount of oil
Oil grade
Dimensions and weights
Length x width x height
Typical operating weight
Fuel tank
Detergent Tank

Technical specifications

pA
+ Uncertainty K
WA
WA
V
Hz
kW
A
--
--
Ohm
°C
l/h (l/min)
m
MPa (bar)
l/h (l/min)
MPa (bar)
°C
l/h (l/min)
kW
kg/h
N
--
dB(A)
dB(A)
dB(A)
m/s
2
m/s
2
m/s
2
--
l
--
mm
kg
l
l
– 11
EN
HDS 5/12 C
230
230-240
1~ 50
1~ 50
2,9
2,9
16
13
IPX5
IPX5
I
0.4526
0.4526
30
700 (11,7)
0,5
1 (10)
500 (8,3)
12 (120)
15 (150)
98
0-30 (0-0,5)
39
3,2
20,1
034
74
3
92
1,3
2,4
0,3
Fuel oil EL or Diesel
0,3
0W40
1060 x 650 x 920
100,6
15,5
15,5
I
27