Technical Specifications; Maintenance And Care - Kärcher HD 30/6 User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
High pressure part
Flow rate
Operating pressure
Permissible pressure
Water connection
Flow quantity
Max. feed temperature
Flow pressure (with ABS storage tank)
Flow pressure (with constructed storage tank)
Diameter inlet (with ABS storage tank)
Diameter inlet (with constructed storage tank)
Electrical connection
Current type
Type of protection
Voltage
Power Input
Dimensions and weights
Dimensions (high pressure module) l x b x h
Dimensions (high pressure module with ABS storage tank) l x b x h mm
Weight (high pressure module)
Weight (high pressure module with ABS storage tank, empty)
Tank capacity of ABS storage tank
Oil quantity for each pump casing
Noise emission
Sound pressure level (DIN EN ISO 11201:2010)

Maintenance and care

Maintenance instructions
The bases of a safe operating of the equip-
ment is thr regularly maintenance accord-
ing to the following maintenance plan.
Use exclusively original parts of the manu-
facturer or those parts recommended by
him like
– replacement and wear parts
– Accessory parts
– Fuel
– Detergent
DANGER
Risk of electric shock!
Remove the voltage from the high pressure
module; for this, switch the high pressure
module main emergency stop switch to "0"
and secure it against being switched on
again.
16

Technical specifications

l/h (l/min)
MPa
MPa
l/h (l/min)
°C
MPa
MPa
mm
mm
Hz
V
kW
mm
kg
kg
l
l
dB(A)
Who may carry out maintenance and
servicing?
Operator
Work designated with the sign "Operator"
may only be carried out by persons who
have been instructed in the safe operation
and maintenance on the wash plant
Customer Service
Work designated with the sign "Customer
Service" may only be done by the fitters of
Kärcher Customer Service.
Maintenance contract
In order to guarantee a reliable operation of
the equipment, we success, you signed a
maintenance agreement. Please refer to
your local Kärcher service department.
5
-
EN
HD 30/6
HD 60/6 K2
1 x 3050
2 x 3050 (2 x 50.8)
6.0
8.7
1 x 3000
2 x 3000 (2 x 50)
40
0.4...0.6
0.1
1x19
50
50, 3~
IPX5
400, IEC 38
15
1100x640x930
1100x790x1490
145
200
163
235
1x85
1.3
87
Maintenance overview report
1 Bypass valve
2 Screw for manual switching
HD 60/10 K2
10.0
11.5
2x19
23
250
285
2x85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd 60/6 k2Hd 60/10 k2

Table of Contents