Front Panel

SYST LED

Table 1-3
Color
Off
Green
Blinking Green
Blinking Amber
Amber
For information on the SYST LED colors during POST, see the
page

XPS LED

The XPS 2200 is not supported in this release.
Note
Table 1-4
Color
Off
Green
Blinking green
Amber
Blinking amber
For information about the XPS 2200, see the Cisco eXpandable Power System 2200 Hardware
Installation Guide on Cisco.com:
http://www.cisco.com/go/xps2200_hw
Catalyst 3850 Switch Hardware Installation Guide
1-10
SYST LED
System Status
System is not powered on.
System is operating normally.
Switch is running POST.
There is a fault with one of the following:
Network module (non-traffic-related)
Power supply
Fan module
System is receiving power but is not functioning
properly.
6-1.
XPS LED
XPS Status
XPS cable is not installed.
Switch is in StackPower mode.
XPS is connected and ready to provide back-up power.
XPS is connected but is unavailable because it is providing power to another device
(redundancy has been allocated to a neighboring device).
The XPS is in standby mode or in a fault condition. See the XPS 2200
documentation for information about the standby mode and fault conditions.
The power supply in a switch has failed, and the XPS is providing power to that
switch (redundancy has been allocated to this device).
Chapter 1
Product Overview
"Diagnosing Problems" section on