Chapter 2
Switch Installation

Switch Stacking and Power Stacking Guidelines

For general concepts and management procedures for switch stacks, see the switch software
configuration guide on Cisco.com.
Before connecting the switches in a stack, keep in mind these stacking guidelines:

Data Stack Cabling Configurations

Figure 2-1
cable. In this example, the switches are stacked in a vertical rack or on a table. This configuration
provides redundant connections.
The configuration example
shows the full-ring configuration that provides redundant connections.
Figure 2-1
Figure 2-2
1-meter and the 3-meter StackWise cables to connect the switches. This configuration provides
redundant connections.
OL-26779-02
Size of the switch and any optional power-supply module. The 1100-W power-supply module is
longer than the other modules. Stacking switches with the same power-supply modules together
makes it easier to cable the switches. For switch dimensions, see
Specifications."
Length of cable. Depending on the configurations that you have, you might need different-sized
cables. If you do not specify the length of the StackWise cable, the 0.5-meter cable is supplied. If
you need the 1-meter cable or the 3-meter cable, you can order it from your Cisco supplier. For cable
part numbers, see the
"StackWise Ports" section on page
Configurations" section on page 2-5
For rack-mounted switch stacks that are members of a StackPower stack as well as a data stack, see
the
"Planning a StackPower Stack" section on page
You can create data stacks with up to four switches in a stack.
is an example of a recommended configuration that uses the supplied 0.5-meter StackWise
(Figure
Data Stacking the Catalyst 3850 Switches in a Rack or on a Table Using the 0.5-meter
StackWise Cables
CONSOLE
MGMT
CONSOLE
MGMT
CONSOLE
MGMT
CONSOLE
MGMT
shows a recommended configuration when the switches are mounted side-by-side. Use the
1-18. The
provides examples of recommended configurations.
2-8.
2-1) uses the supplied 0.5-meter StackWise cable. The example
PWR-C1-715WAC
PWR-C1-715WAC
PWR-C1-715WAC
PWR-C1-715WAC
Catalyst 3850 Switch Hardware Installation Guide
Data Stack Cabling Configurations
Appendix A, "Technical
"Data Stack Cabling
PWR-C1-715WAC
PWR-C1-715WAC
PWR-C1-715WAC
PWR-C1-715WAC
2-5