PROBLEM
Engine will not
crank/start.
Engine runs
rough.
Unit does not
move with
engine running
when using
steering levers.

TROUBLESHOOTING

PROBABLE CAUSE
1. Safety interlock
system is not
engaged or is
faulty.
2. Fuel tanks empty.
3. Discharged
battery.
4. Poor connection
between battery
and battery cables.
5. Spark plug wire(s)
loose or spark
plug(s) faulty.
6. Faulty electrical
system.
7. Faulty engine.
1. Choke engaged.
2. Air filter cartridge
plugged.
3. Faulty engine.
1. The transmission
bypass lever is
engaged.
2. Faulty hydrostatic
belt.
3. Faulty
transmission.
1. Check safety interlock system (see
Safety Interlock System on
page 13).
2. Fill fuel tanks (see FILLING FUEL
TANK on page 15).
3. Charge battery (see Charging the
Battery on page 22).
4. Tighten battery cables and/or clean
battery and battery cables (see
Cleaning Battery and Battery Cables
on page 22).
5. Connect spark plug wire(s) or
replace spark plug(s). Refer to
Engine Manual for detailed
instructions.
6. Contact your Ariens Dealer.
7. Contact your Ariens Dealer.
1. Disengage choke.
2. Clean or replace air filter cartridge.
Refer to Engine Manual for detailed
instructions.
3. Contact your Ariens Dealer.
1. Disengage transmission bypass
lever (see on page 17).
2. Replace hydrostatic belt (see
REPLACING HYDROSTATIC BELT
on page 25).
3. Contact your Ariens Dealer.
GB - 28