Dc/Cv Mig Volt-Ampere Curves; Section 4 - Installation; Installing Welding Generator - Miller Electric Trailblazer Pro 350 Owner's Manual

Engine driven welding generator
Hide thumbs Also See for Trailblazer Pro 350:
Table of Contents

Advertisement

3-8. DC/CV MIG Volt-Ampere Curves

45
40
35
30
25
20
15
10
5
0
0

4-1. Installing Welding Generator

Movement
Y Do not lift unit from end.
OR
Location
OR
OM-4401 Page 14
100
200
300
DC AMPERES
SECTION 4 – INSTALLATION
Airflow Clearance
18 in
(460 mm)
18 in
(460 mm)
Grounding
1
Electrically bond genera-
tor frame to vehicle frame
by metal-to-metal contact.
2
400
500
600
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
3
4
GND/PE
OR
install1 10/00 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of unit.
Curves of other settings fall be-
tween curves shown.
Y Do not weld on base. Weld-
ing on base can cause fuel
tank fire or explosion. Bolt
unit down using holes pro-
vided in base.
Y Always
securely
fasten
welding
generator
transport vehicle or trailer
and comply with all DOT and
other applicable codes.
Y Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y If unit does not have GFCI re-
ceptacles,
use
protected extension cord.
2
203 112
onto
GFCI-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents