300GB models in 3Gb operation
Typical power dissipation under idle conditions in 3Gb operation is 3.02 watts 10.30 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 7). Locate the typical
I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts
on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 11.
300GB (at 3Gb) DC current and power vs. input/output operations per second
300GB models in 6Gb operation
Typical power dissipation under idle conditions in 6Gb operation is 3.04 watts 10.37 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 7). Locate the typical
I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts
on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 12.
300GB (at 6Gb) DC current and power vs. input/output operations per second
S
10K.6 SAS P
AVVIO
RODUCT
M
, R
. C
ANUAL
EV
31