Powerchoice Reporting Methods; Ac Power Requirements; Dc Power Requirements - Seagate ST900MM0006 Product Manual

Savvio 10k.6 sas
Table of Contents

Advertisement

6.1.1

PowerChoice reporting methods

PowerChoice
TM
provides these reporting methods for tracking purposes:
Request Sense command reports
• Current power condition
• Method of entry
Processing the Request Sense command does not impact the drive's power save state.
Note.
Mode Sense command reports (mode page 0x1A)
• Idle conditions enabled / disabled
• Idle condition timer values (100ms increments) (default, saved, current, changeable)
Power Condition Vital Product Data (VPD) Page (VPD page 0x8A)
• Supported power conditions
• Typical recovery time from power conditions (1ms increments)
Start/Stop Cycle Counter Log Page reports (log page 0x0E)
• Specified and accumulated Start/Stops and Load/Unload cycles
Power Condition Transitions Log Page reports (log page 0x1A, subpage 0x00)
• Accumulated transitions to Active, Idle_A, Idle_B, Idle_C, Standby_Y, Standby_Z
6.2
AC
POWER REQUIREMENTS
None.
6.3
DC
POWER REQUIREMENTS
The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive connector.
The standard drive models and the SED drive models have identical hardware, however the security and encryption portion
of the drive controller ASIC is enabled and functional in the SED models. This represents a small additional drain on the 5V
supply of about 30mA and a commensurate increase of about 150mW in power consumption. There is no additional drain on
the 12V supply.