Front Panel Monitoring And Adjustments; Level Indicators; Level Adjust; Mute Indication - Lab.gruppen FP14000 Operation Manual

Dedicated touring amplifiers fp+ series
Hide thumbs Also See for FP14000:
Table of Contents

Advertisement

7.6 front-panel monitoring and
adjustments

7.6.1 Level indicators

Figure 7.6.1: Front panel LED field (per-channel)
The front-panel displays an array of ten LED indica-
tors for level and status monitoring of each amplifier
channel. Indications related to signal levels are as
follows:
Orange CPL (Current Peak Limiter)
Indicates that output signal has reached the limit
of the output devices and limiting is in effect.
Red VPL/CLIP
Indicates that signal has reached
maximum output voltage. (Maximum voltage is
determined by rear-panel VPL settings.)
Indicates output signal levels
Green SIG to -4
in normal operating range
SIG + hI-IMP (green/orange)
signal above –44 dB. Should the SIG indicator
turn red, this indicates a "high-impedance"
or open connection has been detected at the
output. Possible faults include a disconnected
cable or malfunctioning loudspeaker. (In some
cases a normal condition, such as a sub-bass
enclosure with high-impedance at a certain
frequency, can trigger this indication.) If the -10
dB LED illuminates AND the HI-IMP LED turns
orange, then the amplifier has detected an open
load (no loudspeaker connected).
More detailed signal indications are available using
the DeviceControl software application.

7.6.2 Level adjust

Level adjust potentiometers (one per channel) are
located on the front panel adjacent to the LED display.
The potentiometer's operational range is 0 dB to
minus infinity in 31 steps. Attenuation is logarithmic,
with -10 dB at the 12 o'clock position. See table for
levels at other increments.
flashing
Indicates input
Table 7.6.2: Attenuation for front panel poten-
Note that it is not possible to adjust individual chan-
nel attenuation from the NomadLink network or
elsewhere on the amplifier.

7.6.3 Mute indication

Individual channel Mute is indicated by illumination
of the red MUTE LED provided for each channel. If
only the red MUTE LED is illuminated and all other
indications are normal, then the channel has been
muted by a command from the NLB 60E front panel
or the DeviceControl application. Otherwise, an il-
luminated MUTE LED could indicate a fault condition
(see below).
OPERATION AND PERFORMANCE 7
Step
Attenuation
1 (Min)
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31 (Max)
tiometers in steps-to-dB levels
FP+ Series Operation Manual 23
-Inf. dB
-60.5. dB
-48.3 dB
-33.9 dB
-25.8 dB
-21.6 dB
-19.2 dB
-17.4 dB
-16.0 dB
-14.7 dB
-13.7 dB
-12.7 dB
-12.1 dB
-11.3 dB
-10.6 dB
-10.0 dB
-9.3 dB
-8.7 dB
-8.1 dB
-7.4 dB
-6.8 dB
-6.1 dB
-5.3 dB
-4.5 dB
-3.6 dB
-2.7 dB
-1.7 dB
-0.7 dB
-0.3 dB
-0.2 dB
-0.0 dB