FP 6000Q
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
Level
Standby, with remote power off via NomadLink
Powered on, idling
Pink noise (1/8
16 Ω / Ch.
rated power)
32 Ω / Bridged
8 Ω / Ch.
16 Ω / Bridged
4 Ω / Ch.
8 Ω / Bridged
2 Ω / Ch.
4 Ω / Bridged
16 Ω / Ch.
Pink noise (1/4
rated power)
32 Ω / Bridged
*3)
8 Ω / Ch.
16 Ω / Bridged
4 Ω / Ch.
8 Ω / Bridged
2 Ω / Ch.
4 Ω / Bridged
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and
specified here is what is known as the "Active Power" of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be
tripped even if operation is in excess of max. ratings.
i n t e r n a t i o n a L c o n t a c t • i n f o @ L a b g r u p p e n . c o m
-10dB
A
channel
-inf
0
-10dB
B
channel
-inf
0
-10dB
C
channel
-inf
0
-10dB
D
channel
-inf
0
Load
Rated Power
Line Current *2)
115 VAC
320 x4
6.9
640 x2
625 x4
10.9
1250 x2
1250 x4
18.0
2500 x2
1500 x4
22.8
3000 x2
320 x4
11.8
640 x2
625 x4
20.0
1250 x2
1250 x4
37.3
2500 x2
1500 x4
38.9
3000 x2
16 A, CEE7
30 A, Nema L5-30P Twist lock
L a b . g r u p p e n a b • S w e d e n
w w w . l a b g r u p p e n . c o m
Current Draw and Thermal Dissipation
FP+ Series: Dedicated Touring Amplifiers
HI-IMP
CLIP
VHF
SIG -20 -15 -10 -4
VPL CPL
TEM
BRIDGE A+B
MUTE
PWR
SIG -20 -15 -10 -4
VPL CPL
VHF
TEM
HI-IMP
CLIP
FP6000Q
PAL
HI-IMP
CLIP
VHF
SIG -20 -15 -10 -4
VPL CPL
TEM
NOMAD
LINK
BRIDGE C+D
MUTE
SIG -20 -15 -10 -4
VPL CPL
VHF
TEM
HI-IMP
CLIP
FP 6000Q
Watt *1)
230 VAC
In
Out
0
0
134
0
Amp (I)
Watt
3.5
423
160
5.4
700
313
9.0
1215
625
11.4
1575
750
5.9
771
427
10.0
1402
833
18.6
2748
1667
19.4
2872
2000
|
u S c o n t a c t • i n f o @ t c u S . c o m
R
POW
FP SERIES
POW
Thermal Dissipation
Dissipated
BTU/hr
kCal/hr
0
0
0
134
456
115
263
898
226
388
1323
333
590
2015
508
825
2817
710
344
1175
296
569
1942
489
1081
3690
930
872
2977
750
Item no. CDTD_FP6000Q_V4