Nomadlink / Ethernet Network Setup - Lab.gruppen FP14000 Operation Manual

Dedicated touring amplifiers fp+ series
Hide thumbs Also See for FP14000:
Table of Contents

Advertisement

6 QUICK GUIDE OVERVIEW
6.3 NomadLink / Ethernet
network setup
The amplifier includes, as a standard feature, internal
facilities for the NomadLink monitoring and control
network. All features of the NomadLink network are
accessible via a PC running Lab.gruppen's proprietary
DeviceControl software. A single rackspace NLB 60E
NomadLink Bridge & Network Controller accepts the
TCP/IP data stream from the computer and converts it
to the NomadLink protocols. Even when no computer
is connected, the NLB 60E can initiate stand-alone
power on/off and muting functions, as well as report
any fault or warning conditions.
The PC is connected to the NLB 60E using a
standard Ethernet interface and a crossed Cat-5 cable
(peer-to-peer setup). If a HUB or switch is in the
network, standard "straight" Cat-5 cables must be
used. The front and rear Ethernet connections on
the NLB 60E can be used individually, but only one
PC at a time running DeviceControl can access the
subnet.
Many newer laptop computers will allow
peer-to-peer connection with the NLB 60E
using a standard "straight" Cat-5 cable in-
stead of a crossed Cat-5 cable.
The default fixed TCP/IP address of the NLB 60E is
192.168.1.166. The subnet mask is 255.255.255.0.
For further details, please refer to instructions
supplied with the NLB 60E unit.
Figure 6.3:
NomadLink network wiring configuration
"Crossed" RJ45 cable:
Between NLB 60E and PC.
"Straight" RJ45 cable:
Between Ethernet switch or hub and NLB 60E.
"Straight" RJ45 cables:
Between NLB 60E and amplifiers, and from
amplifier to amplifier in a subunit.
NOTE: Connection can be made to either
the front or rear panel or the NLB 60E.
Although two computers may be connected
to the NLB 60E simultaneously, only one is
allowed access to the subnet at a time.
14 FP+ Series Operation Manual
The NomadLink connections use standard "straight"
Cat-5/RJ45 equipped cables. For a safer mechanical
connection it is possible to use Neutrik EtherCon
"XLR-type" housings on the cables.
The OUT port from the NLB 60E must be connected
to the IN port of the first amplifier. The OUT port
from the first amplifier in turn connects to the next
amplifier's IN port to form a daisy-chain The OUT
port on the last amplifier is connected to the IN port
on the NLB 60E to close the loop.
Operation and Performance chapter in this manual,
or the instructions supplied with the NLB 60E, to
ensure the network is configured within these
parameters.
OUT port to the NLB 60E's IN port. Doing so will
improve redundancy and communication speed.
External contact closures and 24 V low/high triggers
can be connected to the GPI connectors on the NLB
60E for control of fire-alarm systems or external
power sequencers. For more details read the instruc-
tions supplied with the NLB 60E.
GENERAL
NOMADLINK
PURPOSE
IN
OUT
INPUT, GPI
ETHERNET
ETHERNET
Ser. N:o
Removed!
FP 10000Q
200-240V
50-60Hz :2500W
Must be grounded/earthed
Made in Sweden
IN OUT
NOMADLINK
IN OUT
NOMADLINK
US National Differences cl.16.3 requires
that NomadLink network cables must be
rated VW-1.
There are electrical limitations to cable
lengths on a NomadLink network, both in
terms of total cable length in the loop and
between any two devices. Read the
Although the network will function as an
open loop under most circumstances, it is
strongly recommended that the loop be
closed by connecting the last amplifier's
BALANCED INPUTS
44dB
150V
70V
41dB
CH D
CH C
CH B
CH A
CH D
38dB
121V
56V
35dB
101V
47V
32dB
83V
38V
29dB
26dB
23dB
1+ CH D+
1+ CH C+
XLR
PIN 1-SCRN
PIN 2-POS
PIN 3-NEG
1- CH D-
1- CH C-
SPEAKER OUTPUTS
CH C+D
CH B
CH A+B
BRIDGE
1+:+
2- : -
WIRING
2+ CH D+
1+ CH B+
1+ CH A+
2+ CH B+
NORMAL: CLASS 2
2- CH D-
BRIDGED: CLASS 3
1- CH B-
1- CH A-
2- CH B-