Pre-Alarm Recording - Sanyo DSR-3000P Instruction Manual

Hide thumbs Also See for DSR-3000P:
Table of Contents

Advertisement

RECORDING IMAGES IN THE ALARM
RECORDING AREA

Pre-alarm recording

Insert the power cord into a wall outlet and turn on the
1
power.
The POWER indicator illuminates, and after approximately 15 seconds, the
EXIT/OSD indicator illuminates. The camera images appear on the monitor,
POWER
and the operating display appears in the top-left corner of the screen.
Note: The operating display can be moved or switched off by pressing the
EXIT/OSD
Setting the time
2
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and
set the date and time. After the setting has been made, press the EXIT/OSD
MENU
button, the date and time appear in the operating display. (See page 40.)
Set pre-alarm recording.
3
Press the MENU button to display the ALARM REC MODE SET menu. Set
ALARM RECORDING to the desired alarm recording setting (example:
REC/STOP
MODE1). The *** setting for PRE-ALARM RECORDING will be set to
"OFF", so change it to "ON". (See page 54.)
Press the EXIT/OSD button to return to the normal screen. "PRE" appears in
the operating display, the ALARM indicator illuminates and pre-alarm
recording starts (the a mark does not appear).
The same monitored image as in the normal recording area is recorded
repeatedly in the alarm recording area.
Recording onto the hard disk proceeds automatically (default setting)
ALARM
according to the following settings. The settings can be changed between
long-period recording and high-quality recording in five steps. (See page 47.)
EXIT/OSD button repeatedly.
See page 11 for details of the operating display.
Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
Picture quality: EN (Enhanced)
Recording method: Field
Recording speed: 0.12 seconds (65H)
Pre-alarm images
are recorded
16
Monitored images
are recorded
Operating display
English

Advertisement

Table of Contents
loading

Table of Contents