Recording settings
G-2

Pre-alarm recording settings

1
Display the <ALARM REC MODE SET> screen as
explained in "Displaying the recording settings
screen", and then turn the S-dial clockwise. (P39)
The "OFF" field of ALARM RECORDING starts
blinking.
MENU
(S)
(J)
2
Set the pre-alarm recording.
1
Turn the J-dial to select "ENABLED" for ALARM
RECORDING, and then turn the S-dial clockwise.
The "***" field of the PRE-ALARM RECORDING
switches to "OFF".
PRE-ALARM RECORDING
2
Turn the J-dial to select "PRE-ALARM
RECORDING", and then turn the S-dial
clockwise.
The "OFF" indicator of PRE-ALARM RECORDING
starts blinking.
3
Turn the J-dial, turn "ON" the PRE-ALARM
RECORDING, and then turn the S-dial clockwise.
The "****" displayed at the REC RATE and
DURATION fields changes to numbers, and a
<WARNING> screen is displayed, with "NO"
blinking.
REC RATE: A 12.5FPS, DURATION: 1MIN
<WARNING>
REC RATE SETTING IN THE MENU WILL BE
AUTOMATICALLY ADJUSTED.
ARE YOU SURE ?
4
Turn the J-dial, select "YES", and turn the S-dial
clockwise.
The cursor moves to "REC RATE".
5
Turn the S-dial clockwise.
57
How to set
<MAIN MENU>
2.RECORD SET
<RECORD SET>
7.ALARM REC MODE SET
<ALARM REC MODE SET>
ALARM RECORDING
: OFF
PICTURE QUALITY
: ENHANCED
AUDIO RECORDING
: OFF
ALARM INTERLEAVE
: ONLY
REC RATE: 12.5FPS,
DURATION: 20SEC
PRE-ALARM RECORDING
: OFF
REC RATE: **** FPS,
DURATION: ****
=> (01731 ALARMS CAN BE RECORDED)
ALARM TRIGGER
: ALARM
MOTION SENSOR
->
: OFF
NO
6
Turn the J-dial to select the REC RATE (example:
8.333), and then turn the S-dial clockwise.
Repeat the same procedure to set the DURATION
(example: 20SEC).
After the arrow symbol (=>) the number of alarms
that can be recorded is displayed.
REC RATE: A 8.333FPS, DURATION: 20SEC
=> (00694 ALARMS CAN BE RECORDED)
3
Press the EXIT/OSD button.
"PRE" appears in the operation display area.
When an alarm is detected, the "ALARM" field starts
blinking.
EXIT/OSD
G-3

Alarm trigger setting

1
Turn the J-dial to the select ALARM TRIGGER
selections and turn the S-dial clockwise.
The "ALARM" starts blinking.
Selections:
ALARM/SENSOR/ALARM AND SENSOR/ALARM OR
SENSOR
ALARM TRIGGER
2
Turn the J-dial, select "ALARM". Then turn the
S-dial clockwise.
The cursor moves back to the ALARM RECORDING
field.
3
Press the EXIT/OSD button.
EXIT/OSD
b Input signals used as external alarms
The signals that can be used as alarms are of two types:
signals detected at the ALARM IN terminal switches, and
alarm signals superimposed on the coaxial signals coming
from cameras.
Alarm total
PRE indicator
01-01-06 00:00:00 REC REPEAT EN A PRE
0000
02
: ALARM